SECURITY LEVEL
INDIVIDUAL ZONE SENS
LEVEL [03]
ZONE=[01]=020
NOTE: The general sensitivity level adjustments are
dominant (pls. see section 4.1.1). Therefore any separate
sensitivity level adjustment of the zones will not be valid
after such preliminary setting.
4.1.3 AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN
(
* only for
ThruScan
sX/sX-i/sX –WP
)
This feature is very rare worldwide and its MENU helps the user to decide and to assign the
required sensitivity level very rapidly.
The assigned sensitivity level in this MENU is approximate. For more precise security requirements;
It is recommended to the user to decide on the necessary sensitivity level by using the displayed
(AD) sensitivity level only as a reference. And proceed the further adjustment manually.
This procedure is strongly suggested for more successful results!
AUTO DESIGNATE
MODE
Auto Designation and Automatic Sensitivity Assignments are set as
follows:
1-Press
SEL(
√
)
button when displayed as on the right.
USED FOR AUTO
DESIGNATE OF
SECURITY LEVEL TO
CONTINUE PRESS SEL
2- To make an automatic assignment, according to the statement
displayed; Pass the objected metal through the WTMD with a person
without any other metal object, when the traffic-light is green,
3- Repeat the procedure in
# 2 -3/2,
4- Repeat the procedure in
# 2-3/3,
5- Thus the WTMD determines the approximate size of the metal that
you’ve passed 3 times and inquires whether you want a general or
zone assignment,
6- If the general assignment is being selected, the unit repeats
procedure 4.1.1 itself.
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(
√
) 3/1
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(
√
) 3/2
WHEN TRAFFIC LED IS
GREEN, ENTER
METAL OBJECT THEN
PRESS SEL(
√
) 3/3
DESIGNATE-DETECTMODE
ALL ZONES 00 ZONE 01
[00]
AUTO DESIGNATE MODE
TO DESIGNATEPRESSSEL
LEVEL [AD]=000
7- Select the zone and assign by repeating the procedure 4.1.1 .
NOTE: Make sure there are no moving metals near the WTMD
and make sure that there are not any moving metals or
passing any metal through the WTMD also avoid touching, shaking the panels, while
the sensitivity assignment procedures.
AUTO DESIGNATE MODE
TO DESIGNATEPRESSSEL
ZONE=[02]=000
NOTE: You cannot return to normal operating mode unless the whole assignment
procedure is completed at the self Designation AD) MENU completely,.
24