Note: WTMD and thus the VU display will only operate whilst the infrared beam is
obstructed.
CAUTION! the first (green) led only indicate that the WTMD is on but not any
operational detection situation.
3.1.4 UPS INDICATOR
If the battery voltage drops below 10.5 volts dc the indicator will begin to
flash; if the battery voltage drops to 9.5 volts dc the indicator will continue
flashing and an intermittent alarm tone will start – if the power is not
restored the WTMD will then automatically shuts itself.
3.1.5
IRDA REMOTE CONTROL RECEIVER
(
*only for
ThruScan
sX/sX-i
)
It is the receiving LED of the pilot Remote Control Unit.
3.1.6 TRAFFIC LIGHTS
The traffic lights will mimic the passage is free and possible. – Green indicates walk –
Red indicates wait.
3.2
TOUCHPADS
A total of five touchpad controls are located on the control unit as follows;
3.2.1
ON - OFF BUTTON
The
ON-OFF
touchpad button turns on and off the WTMD. When first switched on the
WTMD initiates a self-test for ten seconds during which time a ‘test tone’ will be heard.
Please wait for 1 minute after switching on before using the gateway in order to allow
the auto-calibration program to designate/memorize for metal objects around its
environment.
The previous settings and adjustments would be stored when you turn off your
WTMD and will be displayed when on again.
3.2.2
RUN(X) BUTTON
The
RUN(X)
touchpad button returns the WTMD to
RUN(X)/
operation mode after
any programming changes are made using the
SEL(
√
)
button. It is also used as an
“ESC”
button when no changes are made.
3.2.3 SEL(
√
) BUTTON
The
SEL(ect)
touchpad button is for to access and enter the programming modes
and to confirm programming changes. It serves as an
“ESC”
button.
3.2.4 UP&DOWN BUTTONS
The
UP&DOWN
touchpad buttons moves up and down through the
programming options when on the MENU thus the programming mode. These
buttons is called
UP&DOWN
Buttons afterwards.
17