36
4. Rinse with a damp cloth.
5. Remove the protective paper from the upper plate.
6. Fit back the upper plate by referring to paragraph J.4
.
K.4.3
Filters cleaning
7.
Use a Phillips screwdriver (type PH1 or PH2) to unlock
the left and right front bezels.
8.
Gently lift the bottom of the covers and slide them
downwards.
9.
Remove the filters from the masks and carefully clean
them from grease, crumbs and dust, then dry the filters.
10. Separately clean the masks eliminating any deposits
deposited in the ventilation grooves, especially from the
inside, then dry the masks carefully.
11. Use a vacuum cleaner to remove any dirt or dust from
the left and right front louvers prior to reposition the
bezels.
12. Reposition the dry filters in the masks and gently insert
them into the front until they adhere to the edges.
13. Tighten the screws to fix the covers.
Then continue with the steps of daily cleaning with the cleaning
of the tray, refer to K.3.5
and then with the
cleaning of K.3.6
L
APPLIANCE MAINTENANCE
WARNING
Refer to “
L.1
Care information
Care operations have to be carried out by the owner and/or
user of the appliance.
IMPORTANT
Problems resulting from poor or lack of care as
hereinafter described will not be covered by the
warranty.
Intensive use of the appliance can lead to situations where the
limit of use is reached prematurely. Therefore in case the
upper plate, the upper plate flex or the lid have difficulty in
automatically disengaging, we suggest to lubricate the points
as indicated in the following pictures.
L.2
Decommissioning
If the machine cannot be repaired, carry out the decommis-
sioning operations, signalling the failure with a suitable sign,
and request assistance of the manufacturer's Customer Care
service.
L.3
Disassembly
If the appliance has to be disassembled and then reassembled,
make sure the various parts are assembled in the correct order
(if necessary mark them during disassembly).
Before disassembling the machine, make sure to carefully
check its physical condition, and in particular any parts of the
structure that can give or break. Before starting disassembly:
• disconnect the power supply;
• place a sign on the Main Electrical Panel indicating that the
machine is undergoing maintenance and not to carry out
manoeuvres;
• enclose the work area;
• remove all the pieces (if present) in the machine;
• carry out the disassembly operations.
L.4
Maintenance intervals
It is advisable to carry out the checks with the frequency given in the following table:
H2O
FRONT
1
1
2
2
3
3
4
5
Summary of Contents for 603877
Page 1: ...Speedelight EN Installation and operating manual Original instructions 595402902 2022 07 ...
Page 2: ...2 Installation diagram ...
Page 3: ...3 Installation diagram Marine ...
Page 45: ......
Page 46: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...