• The passages enabling personnel to operate on the
appliance must be at least 50 mm wide, except at the rear
of the appliance.
• This space must be increased in case of use and/or transfer
of other equipment and/or means or if exit routes are
necessary inside the workplace.
• To be used to keep the correct distances indicated in the
installation diagram.
F.4
Positioning
CAUTION
• This appliance is not designed for built-
in installation.
• The appliance must be levelled.
• Do not obstruct the vent holes of the
appliance.
• The weight of the appliance is 47 kg. Be
careful!
Unpack the machine, carrying out the following
operations:
1. Wear protective gloves. Refer to “A.2
“ for further information.
2. Cut the straps and remove the protective film, taking care
not to scratch the surface if scissors or blades are used;
3. Remove the cardboard top, the polystyrene corners and
the vertical protection pieces.
4. Install the appliance, taking all the safety precautions
required for this type of operation, also respecting the
relevant fire-prevention instructions.
Install the appliance in a ventilated place. Refer to
“
Warning and safety information
“.
• Do not install the appliance adjacent to any high heat or
grease producing piece of appliance, such as a range top,
griddle, fryer, etc., that could allow radiant heat to raise the
exterior temperature of the appliance.
• For the overall space required and connection dimensions,
refer to the installation diagrams given on the first pages of
this manual.
F.4.1
Adjustment of the minimal distance between the
glass and the upper plate (models equipped only)
• 0 chock: H = approximately 13 mm
• 1 chock: H = approximately 24 mm
• 2 chocks: H = approximately 35 mm
• 3 chocks: H = approximately 46 mm
• 4 chocks: H = approximately 57 mm
NOTE!
The number of chocks is given starting from the
top (see example).
•
4 chocks
•
2 chocks
F.5
Workplace
All the laws, regulations and directives in force in the place of
installation regarding the following must be observed.
• Correct lighting of workplaces.
• Safety in the workplace, accident prevention.
• Compulsory signs and signals.
• Hygiene.
• Work zones and separation of paths for hygienic purposes.
• Fire prevention.
• Low air pollution emissions.
F.6
Feet installation
F.7
Anti-opening lid device (if available in
your model)
During the moving of the appliance insert the special device to
prevent accidental opening of the lid (see the following figure).
1
A
B
x4
2