ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
14 Trouble Shooting Tables
(continued)
PROBLEM
PROBABLY CAUSE
REMEDY
Compressor
will not
start – hums
intermittently
(cycling on
overload)
1.
Low line voltage.
1.
Ask power company to increase
voltage to not less than 10% below
dataplate rating or have transformer
installed. Have electrician check for
adequate wire size.
2.
Improperly wired.
2.
Contact your Electro Freeze
distributor for service.
3.
Open start capacitor or current relay.
3.
Contact your Electro Freeze
distributor for service.
4.
High discharge pressure.
4.
Contact your Electro Freeze
distributor for service.
Poor or slow
product
recovery.
1.
Dirty or blocked condenser, restricted air
flow – high ambient temperature.
1.
Have condenser cleaned by your
Electro Freeze distributor; lower
ambient temperature.
2.
Defective condenser fan motor.
2.
Contact your Electro Freeze
distributor for service.
3.
Component or compressor failure.
3.
Contact your Electro Freeze
distributor for service.
Beater motor
does not
operate.
1.
Head assembly is not installed.
1.
Install head assembly.
2.
Magnetic head switch defective.
2.
Contact your Electro Freeze
Distributor for service.
3.
Loose connection in control circuit.
3.
Contact your Electro Freeze
Distributor for service.
4.
Open starter coil.
4.
Contact your Electro Freeze
Distributor for service.
5.
Faulty capacitor assembly. (Single
phase only.)
5.
Contact your Electro Freeze
Distributor for service.
6.
Faulty beater motor.
6.
Contact your Electro Freeze
Distributor for service.
Summary of Contents for SLX400E
Page 2: ......
Page 10: ......
Page 58: ......
Page 60: ......
Page 70: ...10 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 Figure 10 Assembly View ...
Page 73: ...ELECTRO FREEZE Soft Serve Models SLX400E SLX500 184584 13 ...
Page 74: ...14 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 ...