46
184584
ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
14.1
Virtual Quality Management (VQM) System
Display Trouble Shooting Messages (continued)
What the
display will
read
Action taken
in unit when
error is
present
Detailed
description
Method to
reset error
Probable cause of
Error Code
Remedy
Spigot
Affected side
compressor
and beater
motor are off,
until condition is
reset
If unit is in Clean
or Off Mode, unit
will restore in Off
Mode.
Error will
automatically
reset once
issue has been
rectified
1. Plunger is sticking due
to lack of lubrication, worn
o-rings.
2. Plunger push rod is
sticking/not returning
automatically
3. The wrong plunger push
rod is being used.
4. The plunger switch
spring is worn out.
5. The plunger switch is
malfunctioning
1. Disassemble unit
and check o-rings
and ensure proper
lubrication.
2. Check to ensure
push rod is not bent
or distorted in any
way
3. Install the correct
push rod or call
your Electro Freeze
Distributor to order
the correct push rod.
4. Contact your
Electro Freeze
Distributor for
Service.
5. Contact your
Electro Freeze
Distributor for
Service.
C Spigot
Affected side
compressor
and beater
motor are off,
until condition is
reset
Displays Spigot
if the Left or
Right Side Spigot
switch is engaged
for more than 5
minutes.
Error will
automatically
reset once
issue has been
rectified
1. Plunger is sticking due
to lack of lubrication, worn
o-rings.
2. Plunger push rod is
sticking/not returning
automatically
3. The wrong plunger push
rod is being used.
4. The plunger switch
spring is worn out.
5. The plunger switch is
malfunctioning
1. Disassemble unit
and check o-rings
and ensure proper
lubrication.
2. Check to ensure
push rod is not bent
or distorted in any
way
3. Install the correct
push rod or call
your Electro Freeze
Distributor to order
the correct push rod.
4. Contact your
Electro Freeze
Distributor for
Service.
5. Contact your
Electro Freeze
Distributor for
Service.
Summary of Contents for SLX400E
Page 2: ......
Page 10: ......
Page 58: ......
Page 60: ......
Page 70: ...10 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 Figure 10 Assembly View ...
Page 73: ...ELECTRO FREEZE Soft Serve Models SLX400E SLX500 184584 13 ...
Page 74: ...14 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 ...