30
184584
ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
10.2.1 Standard Priming Instructions
10.2
Priming
Figure 10-3 Mix Feed Tube Assembly
Priming the freezer removes all excess
sanitizer from the freezing cylinder,
and sets the proper overrun for the first
cylinder of product.
1. Make sure that your hands, forearms,
and all freezer assemblies are
sanitized.
2. See figure 10-3. Insert the regulator
into the mix feed tube assembly.
Place mix feed tube on sanitized
surface. Set to desired port size
number. Larger holes are for thicker
products. Insert the mix feed tube
assembly into the hopper drain outlet.
3. Proceed to instructions in section
10.2.1 or 10.2.2 depending on freezer
setup.
Important:
Failure to completely remove sanitizer
or water from the freezing cylinder
before placing in
freeze will
damage the freezer.
3. Allow mix to continue flowing into the
cylinder until the mix in the hopper
stops bubbling. Insert mix feed tube
assembly.
NOTE:
Be sure to install
the mix feed tube assembly so that
the arrow is facing the operator to
allow for easier adjustments.
4. Press the
freeze button to start
the freezer.
5. Repeat Steps 1 - 4 for the other side
of the freezer.
6. Sanitize and install nozzles.
Figure 10-4 Pure mix
INSERT - MIX FEED TUBE
SLEEVE - REAR MIX FEED
TUBE - REAR MIX FEED
O-RING
Summary of Contents for SLX400E
Page 2: ......
Page 10: ......
Page 58: ......
Page 60: ......
Page 70: ...10 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 Figure 10 Assembly View ...
Page 73: ...ELECTRO FREEZE Soft Serve Models SLX400E SLX500 184584 13 ...
Page 74: ...14 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 ...