ELECTRO FREEZE Soft Serve Models SLX400E, SLX500
14 Trouble Shooting Tables
(continued)
Unit does not
operate.
1.
Freezer unplugged.
1.
Plug in freezer.
2.
Fuse or breaker blown at main
disconnect.
2.
Make sure your freezer is connected
to a separate circuit independent
from any other electrical equipment.
Have technician check fuse or
breaker size and check voltage; if not
within 10% of nameplate rating call
power company.
3.
Off on high pressure cut-out control.
3.
Refer to Troubleshooting Table –
Discharge pressure too high.
4.
Off on low pressure cut-out control.
4.
Contact your Electro Freeze
distributor for service.
5.
Disconnected or broken wire in electrical
circuit.
5.
Contact your Electro Freeze
distributor for service.
PROBLEM
PROBABLY CAUSE
REMEDY
Leakage of mix
or water from
drain tube to
drip tray.
1.
Damaged beater shaft seal or installed
improperly.
1.
Replace cup seals on washer. Install
properly.
2.
Beater shaft pitted or damaged where
o-ring rides.
2.
Replace beater shaft.
3.
Beater shaft end play not set properly.
3.
Contact your Electro Freeze
distributor for service.
Compressor
does not
operate or
operates
improperly.
1.
Faulty contactor.
1.
Contact your Electro Freeze
Distributor for service.
2.
Disconnected or broken wire in switch.
2.
Contact your Electro Freeze
Distributor for service.
Dispensed
product too
soft.
1.
Dirty or blocked condenser, restricted air
flow.
1.
Unblock condenser or have cleaned
by your Electro Freeze Distributor.
2.
Component failure.
2.
Contact your Electro Freeze
Distributor for service.
3.
Leak in refrigeration system resulting in
little or no refrigeration.
3.
Contact your Electro Freeze
Distributor for service.
Summary of Contents for SLX400E
Page 2: ......
Page 10: ......
Page 58: ......
Page 60: ......
Page 70: ...10 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 Figure 10 Assembly View ...
Page 73: ...ELECTRO FREEZE Soft Serve Models SLX400E SLX500 184584 13 ...
Page 74: ...14 184584 ELECTRO FREEZE Soft Serve Models SLX400E SLX500 ...