3-20 Programming
PROGRAM:---<
Program to add pulses to;
Enter number, then SEL to go to next screen
CHANNEL:---<
Channel to add pulses to;
Enter number, then SEL to go to next screen
ON: 0<
"On" time of leading edge of first pulse;
Enter 0, then ENT & SEL to go to next screen
OFF:950<
"Off" time of trailing edge of last pulse;
Enter 950, then ENT & SEL to go to next screen
COUNT 10<
Total number of pulses to be added;
Enter 10, then ENT & SEL to go to next screen
DURATION: 50<
Duration of each pulse added;
Enter 50, then ENT & SEL to go to next screen
DURATION: 50
EXECUTE<
Move cursor to EXECUTE, then press SEL to
generate pulses.
DURATION: 35
COMPLETE<
COMPLETE indicates pulses have been generated
<-P-> CH: 1 <EDG
ON: 0 OF: 50
Move cursor to OF and use arrow keys to
review pulse setpoints
Go to SETPOINTS to confirm the pulse train:
Each pulse is 50 increments wide, separated from the next pulse by 50 increments.
Program PULSE COPY as follows:
Pulse Copy (cont’d)
Rate Setup
Menu Path
MAIN SCREEN
to CONFIG MENU
to DISPLAY
RATE SETUP
Purpose
The Rate Setup function allows you to configure the RPM display on the Main Screen.
The Main Screen can display the encoder speed in units of Revolutions Per Minute
(RPM), Bags Per Minute (BPM), or Cartons Per Minute (CPM). The encoder speed can
also be displayed as .5X, 1X, 2X, or 3X actual RPM.
Screen
MPY: 1< DP: 0
DIV: 1 RPM
Units: RPM, BPM, CPM, IPM
Divider: 1 through 63
Number of decimal points displayed: 0, 1, 2, or 3
Multiplier: 0 through 1091