3-14 Programming
Motion ANDing
Menu Path
MAIN SCREEN
to CONFIG MENU
to CHN ANDING MENU
MO-
TION ANDING
Purpose
This function is used to tie the operation of output channels to the Motion Detection
levels programmed through MOTION DETECTION. Each output channel may be ANDed
with either Motion Detection level. If an output is Motion ANDed, it will turn on only
when the encoder RPM is in the range specified for that Motion Detection level, AND
the setpoints programmed for that channel are “on.”
Outputs that must always operate, regardless of machine speed, should not be ANDed
with a Motion Detection level.
Screen
This screen displays the channel number and the Motion Detection level for Motion
ANDing: L1, L2, or OFF. The channel will not be Motion ANDed if the enable is OFF.
Programming
Select a new channel by pressing the INC/DEC keys, or through direct numeric entry
followed by ENT.
Press the SEL key to toggle the ANDing to L1, L2, or OFF.
Operation
• Any number of output channels can be ANDed to a single Motion Detection level.
• Motion ANDing, Input ANDing, and Shift Register ANDing can be combined for any
given output channel.
• When Motion ANDing is activated for a channel, it will apply to that channel in all
programs.
Motion Detector
An output channel can be used as a motion detector by programming it to be on at “1”
and off at “1,” and then ANDing it with the desired Motion Level. This will turn the output
on constantly as long as the machine speed is within the specified Motion Level range.
See Also
MOTION DETECTION
CHN: 12
MOTION AND: L1
Channel number
Motion ANDing level: L1, L2, or OFF.
(Toggle with SEL key)