3-7 Programming
Default Program
Menu Path
MAIN SCREEN
to SETUP MENU
DEFAULT PROGRAM
Background
The PS-6244 controller can store up to 48 programs in its memory. The Default Pro-
gram is the program that controls the output channels when there are no hardware
input signals on terminals 9-13 of TB 1, Figure 7.
The Active Program is the program number that is currently controlling the output
channels. If there are program select inputs on TB 1, those inputs will determine the
Active Program, and the Default Program will be ignored. If no hardware inputs are
active, the Default Program will become the Active Program.
For installations where the program select inputs on TB 1 are not used, the Default
Program will always be the Active Program.
This function displays the current Default Program and allows you to select a different
one.
Screen
Programming
Use the numeric keys and ENT to enter or modify the Default Program.
If hardware input signals are used to select the Active Program, and those sig-
nals are lost due to a malfunction, the Default Program will activate. To prevent
sudden changes in machinery operation that may damage equipment or injure
personnel, program the Default Program with settings that will not cause harm in
the event of sudden activation.
See Also
PGM SEL MODE
DEFAULT PGM: 0
ACTIVE PGM:
0
Enter new Default Program through
Numeric Keypad, then press ENT.