3-16 Programming
Password
Menu Path
MAIN SCREEN
PASSWORD
This screen provides an area to enter a password. It also shows the current program-
ming access level and the status of the Programming Enable terminals on the back of
the keypad, Figure 12.
Enable Levels
There are three programming access levels; OPERATOR, SETUP, and MASTER. See
Figure 21 for a summary of the programming functions available to the different levels.
The codes that correspond to each level are established in the ENABLE CODES screen.
Entering a Password
Enter a password through the numeric keypad followed by ENT. As you press the
number keys, the asterisks will be replaced by dashes. If you make a mistake, press
CLR to erase the last key you pushed.
Output Status
Menu Path
MAIN SCREEN
to SETUP MENU
to I/O STATUS
to OUTPUT
STATUS
Purpose
This screen shows the On/Off state of the output channels.
If any output positions have been programmed as analog outputs, the On/Off status will
show “A” instead of “0” or “1.”
Selecting Outputs
To change the set of outputs displayed, press the SEL key.
12345678 OUTPUT
01001001 1-8<
Output On/Off Status (O=Off, 1=On)
Output Numbers (1-8)
Both Models, Outputs 1-8
901234567 OUTPUT
0100100AA 9-17<
Analog Modules shown with "A"
Output Numbers (9-17)
PS-6344-17, Outputs 9-17
90123456 OUTPUT
01001000 9-16<
Output Numbers (9-16)
PS-6344-25, Outputs 9-25
789012345 OUTPUT
0100100AA 17-25<
Analog Modules shown with "A"
Output Numbers (17-25)
PASSWORD:****<
LEV:NONE INP:OFF
Password entry area
Keypad programming terminal input status
Current programming level (hardware or software)