3-21 Programming
Rate Setup (Cont'd)
Press the SEL key to toggle display mode or rate. Following is a chart summarizing the
relationships between encoder speed, units, and rate multiplier:
If
And
Then an
Is
Units
Rate
Encoder
Displayed
Are…
Is…
Speed Of…
As…
RPM
.5X
100 RPM
50 RPM
1X
100 RPM
100 RPM
2X
100 RPM
200 RPM
3X
100 RPM
300 RPM
BPM
.5X
100 RPM
50 BPM
1X
100 RPM
100 BPM
2X
100 RPM
200 BPM
3X
100 RPM
300 BPM
CPM
.5X
100 RPM
50 CPM
1X
100 RPM
100 CPM
2X
100 RPM
200 CPM
3X
100 RPM
300 CPM
RPM Update Rate
Menu Path
MAIN SCREEN
to CONFIG MENU
to DISPLAY
RPM UPD RATE
Purpose
The RPM Update Rate is how often the RPM display on the Main Screen is updated.
This rate can be programmed to be 1/Sec, 2/Sec, or 10/Sec.
Screen
Press the SEL key to toggle the selection.
SCALE
FACTOR: 360<
Number of increments each revolution is broken into
RPM UPDATE
RATE: 1/S<
RPM Update Rate: How often RPM display on main
screen is updated; 1/Sec, 2/Sec, or 10/Sec.
Scale Factor
Menu Path
MAIN SCREEN
to CONFIG MENU
to HARDWARE MENU
SCALE
FACTOR
Purpose
The Scale Factor screen displays the number of increments into which one encoder
revolution is divided. For the PS-6244 special unit, Scale Factor is fixed at 1000.