30
3.9.2.3
Output ontrol settings by event time
This chapter describes a possibility to control C1 and C2 outputs using timetable (scheduler). It can be, for instance, atomatic tur-
ning on every day at 18:00 and turning off after 5 hours.
The parameters are changed by sending the following SMS message to the system Esim252:
XXXX – user password. OCTEx - output control by event time; value can be OCTE1 (C1 output) or OCTE2 (C2 output). Value structure
is CnVal, when Cn is command name (2 letters), and Val-its value.
Value (CnVal) – table of values
Cn – command
name (2
letters)
Val –
possible
command
meaning.
Command
description
Initial factory
default values
Comments
Setting enabling/
disabling time
WT
h.m
h hour m
minutes
Indicates the time for
enabling or disabling
output in hours and
minutes
E. g. WT18.10 means event start time. It can be
enabling and disabling. It depends on the set
ST value. A period PT must also be indicated,
otherwise relay status will not change. See below.
Setting output
status, whether
it is enabled or
disabled
ST
1
Relay is turned on
ST1
Output is
turned on
E. g. ST1 means that when the set time comes the
output is turned on by WT command.
0
Relay is turned off
E. g. ST0 means that when the set time comes the
output is turned off by WT command.
Setting the period
of turning on/off
PT
h.m
h hour m
minutes
Indicates the time in
hours and minutes for
which output status is
changed.
E. g. PT1.20 means that after automatic enabling/
disabling which is indicated in WT command relay
status is changed to opposite for 1 hour and 20
minutes.
Setting
confirmation call
for period start
CS
1
Users are notified
about period start by
a confirmation call
CS1 means that the preset user is informed about
the period start of output turning on or off via
short call. The user is set by using UC command.
See below.
0
Users are not notified
about period start by
a confirmation call
СS0
Call is not
made
CS0 means that nobody is informed about period
start by a call.
Setting
confirmation call
for period end
CE
1
Users are notified
about period end by a
confirmation call
CE1 means that the preset user is informed about
the period end of output turning on or off via short
call. The user is set by using UC command.
See below.
0
Users are not notified
about period end by a
confirmation call
СE0
Call is not
made
CE0 means that nobody is informed about period
end by a call.
Confirmation call
duration
CT
1; s
The user receives
a confirmation call
when the output is
turned on;
s- call time in seconds
СT12
The first digit is a command; the last digit refers
to call time in seconds. E. g. СT12 means that if
confirmation call mode is enabled, whether for
period start or end, the call will be forwarded to the
user when output is turned on. The system will call
for 2 seconds.
XXXX_SMSEXTRA:OCTEx:Value1,Value2,……,ValueN
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“