As per factory default settings C1 output control via calls is disabled for all users, it is necessary to enable this feature and to set the
users who will be able to control the output. Besides, it is also necessary to set output status for every user when he/she makes a call
to the system. In this case the output must be turned on and the duration must be 1 second; afterwards the output returns to the
previous state. Call Back feature must be enabled for user NO5 and it is necessary to choose the length parameters for that call. Also,
confirmation SMS messages have to be enabled for user NO3.
a) First of all Esim252 system relay output has to be connected to the connectors of gate control unit.
b) The following configuration SMS message must be sent to Esim252 system:
where COC1 means C1 output control by call is enabled for users NO1, NO3-NO5.
CS5 means that Call Back feature is enabled for user NO5 after output C1 status changes.
CT513 means that user NO5 will receive a confirmation call when the output gets activated and call duration is 3 seconds.
SS3 means that user NO3 will be informed about output C1 status change by SMS message.
MS10 means that the output is activated when user NO1 calls the system.
MS30 means that the output is activated when user NO3 calls the system.
MS40 means that the output is activated when user NO4 calls the system.
MS50 means that the output is activated when user NO5 calls the system.
MS1T0.0.1 means that output status is changed for 1 second when user NO1 calls the system.
MS3T0.0.1 means that output status is changed for 1 second when user NO3 calls the system.
MS4T0.0.1 means that output status is changed for 1 second when user NO4 calls the system.
MS5T0.0.1 means that output status is changed for 1 second when user NO5 calls the system.
Task NO2:
Configuring the system so that house gates could be opened via free calls by the housekeeper (NO1) and his family members
(NO3), (NO4) and (NO5). After every successful gate opening the user NO5 wants to receive a confirmation call (Call Back) the
duration of which is 3 seconds, and the user NO3 wants to receive a confirmation SMS message.
XXXX_SMSEXTRA:COC1:CE1345,CS5,CT513,SS3,MS10,MS30,MS40,MS50,MS1T0.0.1,MS3T0.0.1,MS4T0.0.1,MS5T0.0.1
Housekeeper
NO1
Gate controller
ESIM151
Family member
NO3
Family member
NO4
Family member
NO5
Confirmation
SMS
Control
Call
Confirmation
Call
GATES
3 sek.
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
Summary of Contents for ESIM252
Page 1: ...GSM CONTROL SYSTEM ESIM252 ...
Page 33: ...USER MANUAL ELDES ESIM252 V1 0 33 ...
Page 34: ...34 For notes ...