USER MANUAL ELDES ESIM252 V1.0
31
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
0; s
The user receives
a confirmation call
when the output is
turned off;
s- call time in seconds
СT08
The first digit is a command; the last digit refers to
call time in seconds.
E. g. СT08 means that if confirmation call mode
is enabled, whether for period start or end, the
call will be forwarded to the user when output is
turned off. The system will call for 8 seconds.
Setting the user
who receives
confirmations
about period
start/end
UC
1,2,3,4,5
Sets which user is
notified about period
start/end.
UC1
E. g. UC2 means that all confirmations will be
delivered to user No2.
Only one user can be selected.
Setting
confirmation
SMS message for
period start
SS
1
Users are notified
about period start by
SMS message
SS1 means that the preset user is notified about
period start of turning on/off output by SMS
message. The user is set by using UC command.
See below.
0
Users are not notified
about period start by
SMS message
SS0
SS0 means that nobody is informed about period
start by SMS message.
Setting
confirmation
SMS message for
period end
SE
1
Users are notified
about period end by
SMS message
SE1 means that the user is also notified about
output turning off by SMS message.
0
Users are not notified
about period end by
SMS message
SE0
SE0 means that nobody is informed about period
end by SMS message.
Example of output C1 configuration for a schedule:
This message configures C1 output parameters using a schedule.
WT20.15 means that output turning on time is set for 20:15 every day.
ST1 means the user set the output to turn on on that time.
PT8.5 means that the output is turned on for 8 hours and 5 minutes, and after that it turns off and turns on again at 20:15 the
following day etc.
UC2 means that information about turning on/off is sent to user’s No2 telephone.
CS1 means that the user is notified by a callback about output turning on; the duration of the call is set by parameter CT13. CT13
means that the system calls for 3 seconds.
CT06 means that when the output turns off after 8 hours and 5 minutes the user is notified by a call again, but call duration is 6
seconds.
SE1 means that the user is also notified about relay enabling by SMS message.
To see the preset values for any command send SMS message with the same format that you use when changing parameters; only
Value structure will have no value:
XXXX – user password. OCTEx - output control by event time; value can be OCTE1 (C1 output) or OCTE2 (C2 output). Value structure
is Cn, where Cn is command name (2 letters).
E. g. XXXX_SMSEXTRA:OCTE1:CB,CT,SB
XXXX_SMSEXTRA:OCTE1:WT20.15,ST1,PT8.0,UC2,CS1,CT13,CT06,SE1
XXXX_SMSEXTRA:OCTE1:Value1,Value2,……,ValueN