59
18.
Loosen the sensor using a suitable size spanner and screw out. Next remove the
plug from the main electronic circuit board (both size and position have been
changed) and pull out the whole cable in the direction of the sensor.
19.
Lay the cable of the new sensor behind the heat exchanger, plug in AMP – mini-
plug to the corresponding plug slot in the main circuit board and using
conductive paste screw the new sensor back into the heat exchanger and tighten.
20.
The coffee sensor (bottom heat exchanger) is likewise on the right-hand side of
the heat exchanger. It is however positioned below, at the front on the right, at „5
O’clock“ and in the current production series is somewhat difficult to access (in
the future, the “window” on the bottom right of the housing will be made larger,
to make handling easier).
The yellow two-headed
arrow shows the hot water
sensor. Loosen using a
suitable size spanner!
Shown is the sensor
for coffee water
temperature. In the
event that the nut
cannot be reached
with the spanner,
loosen the copper
elbow union at the
front and displace
to the right, thereby
creating room for
the sensor to be
accessed.
Summary of Contents for SUPREME DED400XP1