58
Position the new >>hot water sensor<< with black wires, together with both earth wires
and the earth seal under the insulating tape. Caution: rub a quantity of conducting paste
on to this sensor and around the hole in the heat exchanger. When repositioning, push to
squeeze any excess adhesive and carefully wipe away. Next, insulate he single wires up to
the sensor casing and position so that no contact can be made between them and no
contact with the metal is possible.
17.
The next section will explain how to replace the new sensors that were introduced
commencing from Wk 42 in 2003 with a view to making the disassembly and re-
assembly procedure to replace sensors easier.
The position and the type of sensors were changed. The hot water and steam
sensor is now positioned on the right-hand side near the top, on the top heat
exchanger in a „2 O’clock position“