In the photos on the left
and right, you can see the
Flowmeter;
Remove in-let tube (water
from water container) and
attach a new, more robust
tube of a suitable length.
As a precaution, check the
flowmeter.
Turn the cover of the
flowmeter from >>9
O’clock<< to >>8
O’clock<<
(Bayonet-coupling).
Carefully remove cover.
Do not lose red seal
Check whether the small
impeller wheel with
magnets turns freely. If
yes, replace cover and turn
clockwise to lock.
5.
Now, you need to >>free up<< a further section of the machine to proceed with
changing the pump. Firstly, the front control panel needs to be disassembled. This
can be done by removing the two screws, on the right and left, under the panel.
Remember to remove the knob first. Remove right screw then the left one. See
photos!