4
4.
Firstly, using the >>M 10 spanner<< carefully loosen the nut at the base of the L-
bend element by >>turning anti-clockwise<<.
Attention: There is a threaded connection attaching the L-bend element to the water
in-let group. This thread is small and delicate. On the outer thread of the L-bend
element there is a mini seal that should not be lost. It is essential that this seal is
replaced when the part is screwed back in later.
Take out element with plastic pressurised in-let tube and place it temporarily to one
side.
5.
Next, using the >>M 13 spanner<< remove the water in-let assembly
Once the M13 nut has been
removed, do the same thing with
the top and lower metal plates.
Finally, the sunken group can be
pushed out below by following
the instructions in this section