OPERATION
04/2022
35
NP-DK50-Nx2VTM-AD-EN-6_04-2022
OPERATION
ONLY TRAINED PERSONNEL
MAY
OPERATE
THE
EQUIPMENT!
Risk of electric shock.
In
case
of
emergency,
disconnect
the
compressor
from the mains (pull out the
mains plug).
Burn or fire hazard.
When
the
compressor
is
running, the connecting hose
between the compressor and
dryer and parts of the dryer and
aggregate may be hot enough to
burn people or other material.
Warning
-
compressor
is
controlled automatically.
Automatic
start.
The
compressor
automatically
switches on when the pressure
in the air tank drops to the
pressure switch’s lower limit
level.
The
compressor
automatically switches off once
the pressure in the tank reaches
the shut-off pressure
.
Potential
for
damage
to
pneumatic components.
The working pressure settings
for the pressure switch set by
the manufacturer cannot be
changed.
Compressor
operation at a working pressure
below the switching pressure
indicates high air usage (see the
Troubleshooting chapter).
Risk of damage to the dryer.
The dryer may be damaged if
operated
at
ambient
temperatures that are higher
than the maximum working
temperature
(ambient
temperature >30°C or inlet air
temperature of >100°C)
Required drying performance
can only be achieved when
following the defined operating
conditions.
Drying performance will decline
and the achieved dew point will
drop if the dryer is operated at
any
pressure
below
the
minimum working pressure.
Summary of Contents for DK50 4x2VT/M
Page 1: ...DK50 4x2VT M DK50 6x2VT M User manual...
Page 2: ......
Page 10: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 10 04 2022 DK 50 6x2VT M...
Page 14: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 14 04 2022 Fig 2 Adsorption dryer...
Page 32: ...INSTALLATION NP DK50 Nx2VTM AD EN 6_04 2022 32 04 2022 15 PNEUMATIC DIAGRAMS DK50 4x2VT M...
Page 33: ...INSTALLATION 04 2022 33 NP DK50 Nx2VTM AD EN 6_04 2022 DK50 6x2VT M...
Page 58: ......
Page 59: ......