OPERATION
04/2022
39
NP-DK50-Nx2VTM-AD-EN-6_04-2022
Alarm signals have priority over
maintenance interval signals.
As such, the light will indicate
an alarm from any of the air
pumps.
One the alarm is over, the
service interval is indicated by
the activated HA beacon.
17. SWITCHING OFF THE COMPRESSOR
Turn off the controller program for maintenance or other reasons that require the controller be shut
down.
Repeatedly press ▼ until the
display shows the current date and
time
Press ESC to show the following
menu:
Use Set.. to set the current time.
Press▲ or ▼ to move the “>” cursor
on the display to
Stop
and press
OK
to confirm.
Never press OK if the cursor “>”
is at Set Param! Switching to
this menu opens windows with
software
functional
blocks.
Changes to the parameters in
these blocks have a direct
effect on the functionality of the
equipment!
You will be asked if you really want to quit
the program.
•
Press▲ or ▼ to move the
“>” cursor on the display to
Yes
and
press
OK
to confirm.
Now turn off circuit breakers FA13 and FA14.
Vent the air tanks by disconnecting from the
central compressed air circuit and opening the
outlet valve (Fig. 1) or the drain valves
Summary of Contents for DK50 4x2VT/M
Page 1: ...DK50 4x2VT M DK50 6x2VT M User manual...
Page 2: ......
Page 10: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 10 04 2022 DK 50 6x2VT M...
Page 14: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 14 04 2022 Fig 2 Adsorption dryer...
Page 32: ...INSTALLATION NP DK50 Nx2VTM AD EN 6_04 2022 32 04 2022 15 PNEUMATIC DIAGRAMS DK50 4x2VT M...
Page 33: ...INSTALLATION 04 2022 33 NP DK50 Nx2VTM AD EN 6_04 2022 DK50 6x2VT M...
Page 58: ......
Page 59: ......