INSTALLATION
NP-DK50-9x4VRTM-AD-EN-5_04-2022
26
04/2022
AD dryer compressed air inlet
•
Connect the compressed air outlet from
the compressor (Fig. 15) to the dryer inlet
(1).
•
A G 1” connection is installed.
Fig. 15: Compressed air inlet
Burn or fire hazard! Caution! Hot
surface!
When installing the connecting
hoses at the inlet to the air dryer,
ensure that the temperature is
not hazardous if it was to come
into contact with an operator or
other material.
AD dryer compressed air outlet
•
Connect the air outlet from the dryer (1) to
the inlet on the air tank.
•
A G 1” connection is installed.
Fig. 16: Compressed air outlet
Condensate outlet from dryer
•
Connect a hose to the outlet (1)
from the automatic condensate
drain (2) to drain piping or to the
provided collection vessel.
A noise silencer is recommended when
connecting directly to drain piping.