Page 1: ...8 GALLON OIL FREE AIR COMPRESSOR Item 6923 05 Model TAW 2030 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL ...

Page 2: ... 5 Electrical Requirements P 6 General Safety Rules P 7 8 List of Main Parts Tech Specifications P 9 Contents of Packaging Installation P 10 Operation P 11 13 Maintenance P 14 Trouble Shooting P 15 17 Service Center P 17 Warranty Information P 18 Warranty Card P 20 ...

Page 3: ...into a properly grounded outlet which provides correct voltage 120 V and adequate fuse protection Check power cord for signs of crushing cutting or heat damage Replace faulty cord before use Keep all connections dry and off the ground Do not allow electrical cords to rest in water or in such a position where water could come in contact with them Do not touch plug with wet hands Do not pull on the ...

Page 4: ...ects against or on top of air compressor Operate air compressor at least 12 inches away from any wall or obstruction that would restrict proper ventilation Drain air tank daily or after each use to prevent moisture buildup in the air tank If air tank develops a leak replace the air tank immediately Never repair weld or make modifications to the air tank or its attachments Never make adjustments to...

Page 5: ...ls or accessories Always maintain a safe distance from people and animals while operating the air compressor Do not move the air compressor while air tank is under pressure Do not attempt to move the air compressor by pulling on the hose Additional safety guidelines for compressors In order to avoid any danger for persons or damage of the compressor you must stick to the following safety guideline...

Page 6: ...ny use All safety and protection devices or slightly damaged parts must be inspected for proper function before any use Check to see that all of the moving parts are working properly and are not jammed All parts have to be mounted correctly and have to meet all conditions for proper operation of the compressor All damaged protection parts have to be repaired or replaced by an authorized service st...

Page 7: ... is equipped with an electric cord having an equipment grounding conductor and a grounding plug as shown The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided If it will not fit the outlet have the proper outlet installed by a qualified electrician A temporary adapter may not be used...

Page 8: ...e of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury 2 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Wear protective goggles when operating the machine It is recommended to wear protective goggles gloves sturdy non slipping shoes and an apron 3 Av...

Page 9: ...ier to control 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools 8 Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used...

Page 10: ...e gauge 8 pressure hose connectors 9 handle 10 motor housing 11 wheels 12 safety relieve vale TECHNICAL SPECIFICATIONS Model Number TAW 2030 Rating Voltage 120V 60 Hz Power Consumption 1 5 KW 2HP Motor speed 3400min Displacement 3 9 CFM 40psi 3 0 CFM 90psi Tank Volume 8 Gallons Max Pressure 115 PSI Protection Class F Degree of Protection IP20 Weight 60 Lbs ...

Page 11: ... bolts f 2 lock nuts g 2 screw nuts If any of the above items are missing please contact our service department at 1 888 367 7373 http wwwk wk usa com for replacement INSTALLATION 1 Place wheel bolt through wheel 2 Attach wheel bolt to mounting bracket 3 Slide lock nut on the wheel bolt 4 Screw nut on the wheel bolt 5 Repeat to install second wheel 10 ...

Page 12: ...ecessary The compressor must operate only in dry environment Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation Place the power cable in a way that it does not interfere your work and that it is not damaged Before connecting the compressor to the power supply always check the switch is in position OFF see FIG 1 Protect the power cable against heat oil o...

Page 13: ...t the air tool with the air hose 7 If you will not start to work immediately switch the compressor off and disconnect from the power supply FIG 3 FIG 4 CAUTION The regulated pressure may not exceed the maximum working pressure of your connected air tool If you notice any unusual noise or vibration stop the air compressor and refer to troubleshooting 12 ...

Page 14: ...essor to cool down FIG 5 Storing the compressor Switch off the compressor and disconnect from the power supply Before storing the compressor and the accessories they have to be free of compressor air Open drain valve at bottom of air tank and drain all water before storing see FIG 6 The compressor has to be stored in a dry and safe please so that it is out of reach of children or other unauthorize...

Page 15: ... the bottom of the tank counterclockwise until compressed air will escape Any condensed water will be exhausted at the same time Inspect air filter and air vents Remove any material that my have gotten stuck in the are vents Clean the exterior of the compressor Wipe off any dirt or dust that has accumulated on the air tank and housing Every month Check the safety valve for leaks or dirt If necessa...

Page 16: ... improve fittings of tubes Air leaks at or inside check valve Malfunctioning or dirty check valve A malfunctioning check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off Drain tank then remove and clean or replace check valve DO NOT OVERTIGHTEN Air leaks at pressure switch release valve Malfunctioning pressure swit...

Page 17: ...spray on internal motor parts Fuse blown circuit breaker tripped Pressure release valve on pressure switch has not unloaded head pressure Let motor cool off and overload switch will automatically reset Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Check for proper gauge wire and cord length Remove and clean or replace Check wiring connection insid...

Page 18: ...lace air intake filter Do not operate the air compressor Regulator knob has continuous air leak Regulator will not shut off air outlet Pressure release valve on pressure switch has not unloaded head pressure Damaged regulator Replace regulator SERVICE CENTER Repairs Any repair on your compressor has to be carried out only by an authorized or qualified service station If you have any question in re...

Page 19: ...oduct Under no circumstances shall there be liability for any loss direct indirect incidental special or consequential damage arising out of in connection with use of this product This warranty is valid only in the United States of America This Warranty gives you specific legal rights However you may have other rights that vary from state to state Some states do not allow limitation on implied war...

Page 20: ...19 ...

Page 21: ...iginal parts and workmanship until June 13th 2006 or 1 year with proof of purchase Please fill in your details below and send it together with the product and purchase receipt Please read the Limited Warranty conditions mentioned in this instruction manual Customer Name Street City State ZIP Code Purchase Date Description of Defect 20 PLEASE DETACH THIS SECTION AND RETURN IT WITH YOUR PRODUCT To a...