INSTALLATION
NP-DK50-9x4VRTM-AD-EN-5_04-2022
28
04/2022
The
manufacturer
recommends
protecting cabling loose on the floor
(W25 and W23) with a cable bridge.
•
Connect the individual power cord
conductors to the power terminals L1,
L2, L3, N(BU), PE(GNYE). (Fig. 23)
•
Recommended configuration of phase
conductors: L1-BN, L2-BK, L3-GY.
•
Cord type (minimum requirements)
H05 VV-F_ 5G10
•
Route the power cord out of the
enclosure as illustrated. (Fig. 22)
Fig. 19: Connecting the compressor to the dryer