INSTALLATION
NP-DK50-9x4VRTM-AD-EN-5_04-2022
18
04/2022
INSTALLATION
Risk of incorrect installation.
Only a qualified technician may
install the compressor and place
it into operation for the first time.
Their duty is to train operating
personnel
on
the
use
and
maintenance of the equipment.
An
entry
is
made
in
the
equipment installation record to
certify installation and operator
training. (see the Annex chapter)
10. INSTALLATION CONDITIONS
•
The compressor may only be installed
and operating in dry, well-ventilated
and clean environments under the
conditions specified in the Technical
Data chapter.
Risk of damage to the device.
The equipment may not be
operated
outdoors
or
in
otherwise
wet
or
damp
environments.
Risk of explosion.
Do not use the equipment in the
presence of explosive gases,
dust or combustible liquids.
•
The compressor must be installed so
that it is accessible at all times for
operating and maintenance. Please
ensure that the nameplate on the
device is readily accessible.
•
The compressor must stand on a flat,
sufficiently stable base (be aware of
the weight of the compressor, see the
Technical Data chapter).
•
The compressor on the operator’s
side must be at least 70 cm from the
wall to allow air flow for cooling
purposes and to ensure the safety of
the
operator
and
maintenance
personnel.
•
Approximately 70% of the electrical
energy used by the compressor air
pumps is converted to heat, and
therefore the rooms in which the
compressor is installed must have
additional
ventilation
to
provide
sufficient air exchange for cooling
purposes (see the Technical Data
chapter).
Burn or fire hazard! Caution! Hot
surface!
Portions of the compressor, dryer
and connecting hoses between
the dryer and compressor may be
hot
and
reach
hazardous
temperatures during compressor
operation
that
may
harm
materials or operating staff.
High temperature hazard
Placing air flow impediments
upstream or downstream of the
cooler
is
prohibited.
The
temperature
of
internal
and
external parts of the equipment
may rise to hazardous levels.
You may notice a “new product”
odour when you first place the
product into service (for a short
period of time). This odour is
temporary and does not impede
the normal use of the product.
Ensure the space is properly
ventilated after installation.
Summary of Contents for 447000001-066
Page 1: ...DK50 9x4VRT M User manual...
Page 2: ......
Page 66: ...ANNEX NP DK50 9x4VRTM AD EN 5_04 2022 66 04 2022 ANNEX 22 MAPPING PARAMETERS...
Page 67: ...ANNEX 04 2022 67 NP DK50 9x4VRTM AD EN 5_04 2022...
Page 69: ......
Page 70: ......
Page 71: ......