-83-
Electrical Adjustment
c
LCD panel L/R setting
There are two type( Type L, Type R) for the LCD/Prism
Assy. The adjustment data is stored in the memory IC on
the main board.
As the used type is indicated on the optical unit and
LCD/Prism assy, perform this adjustment to match to its
type indication.
1. Enter the service mode.
2. Check the data value. (140 - 0)
Group No.
Value Panel type
140 - 0
0
L
140 - 0
20 R
3. To change the set panel type, select 140-1.
Group No.
Value Panel type
140 - 1
0
L
140 - 1
10 Initial
140 - 1
20 R
The initial data of 140 -1 is "10". To set the value for Type
L, set the value to "0". To set the value for Type R, set the
value to "20". When the value set "0" or "20", it automati-
cally returns to initial data "10" after the setup.
x
Power supply adjustment
Equipment
Digital voltmeter
Test points
K6F-1(+) and K6F-5(-) on AC-DC
board
Input AC Voltage
230V
Adjust the volumes to be specified voltage as follow;
Volume
Voltage
VR631
24.5 ±0.1Vdc
This adjustment is not required even if the AC-DC
board is replaced because this adjustment is carried
out before parts shipment.
Equipment
Digital voltmeter
Input AC Voltage
230V
Connect a digital voltmeter to test points and adjust the
volumes to be specified voltage as follow;
Test Points on PFC board Volume
Voltage
K16B1 (+) K16B2 (-)
VR1601
390Vdc
K16C1 (+) K16C2 (-)
VR1651
390Vdc
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
z
Output voltage adjustment
This adjustment is not required even if the PFC board
is replaced because this adjustment is carried out be-
fore parts shipment.
v
Auto calibration (PC)
Input mode
Input 1 [RGB (PC Analog)]
Input signal
XGA computer signal
Signal pattern 16-step gray scale
1. Enter the service mode.
2. Select Group "
260
", No. "
0
" and set the Data value
"
0
" to "
1
". The projector begins auto-calibration and
then "OK" will appear on the screen.
b
Auto calibration (Video)
Input mode
Input 2 [Video]
Input signal
Composite video signal
Signal pattern 8-color bar
1. Enter the service mode.
2. Select Group "
260
", No. "
0
" and set the Data value
"
0
" to "
1
". The projector begins auto-calibration and
then "OK" will appear on the screen.
Summary of Contents for LC-XT6
Page 192: ...192 IC Block Diagrams CXD3548 Gamma IC401 CXA7009 S H IC501 IC531 IC561 IC1501 IC1531 IC1561...
Page 193: ...193 IC Block Diagrams FA5501 PFC IC1601 IC1651 HIN202 RS232C Driver IC3801...
Page 195: ...195 IC Block Diagrams AX11005 Network IC8301 TE7783 I O Expander IC1801...
Page 196: ...196 IC Block Diagrams...
Page 204: ...SPL 8 LC XT6 Exploded Views M01 4 M01 5 Lens shift assembly M01 1 M01 3 M01 2...
Page 209: ...SPL 13 LC XT6 Exploded Views Optical filter LC CS L19 Integrator assembly S06 L11 S06...
Page 211: ...SPL 15 LC XT6 Exploded Views Relay lens OUT assembly L06 S06 S06...
Page 212: ...SPL 16 LC XT6 Exploded Views L08 L07 In the Optical unit L15 L15 L05 L22 L14 L13 L21 L09 L10...
Page 213: ...SPL 17 LC XT6 Exploded Views Optical filters assembly Mirror assembly L16 L16 L18 L17...
Page 214: ...SPL 18 LC XT6 Exploded Views Labels W09 W07 W01 W01 W06 W08 W04 W04 W04 W03 W02 W05...
Page 218: ...SPL 22 LC XT6 Mechanical Pats List...