-95-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
200
Option
0 Logo Display Prohibition
0:Menu 1:Forced
0 - 1
0
1 RS232C Baud rate
0: 19200bps 1: 9600bps
0 - 1
0
4 CABLE SW
Long Cable 0: Disable 1: Enable
0 - 1
0
6 Device Refresh Disable
0: Enable 1: Disable
0 - 1
0
8 PJ-NET HUNGUP CHK
0: Disable 1: Enable
0 - 1
0
51 Filter Warning Display
1:On 0:Off
0 - 1
1
53 Filter Counter Reset Times
Read only
0 - 255
0
54 Factory Default Executed Times
Read only
0 - 255
0
56 Menu Position (X)
X Offset
0 - 1024
0
57 Menu Position (Y)
Y Offset
0 - 1024
0
72 COMPONENT/RGB SW
0: Disable 1: Enable
0 - 1
1
140 OFFSET ADD MODE
Offset Tem Add Mode Display
0: No Addition, 1: Addtion
-
0
141 OFFSET ADD CHNG
Apply Offset Change when the data is set 10
0 - 10
0
142 OFFSET
Offset Temp
-
10
143 TIMES OF OFFSET CHANGE
0 - 255
0
144 TIMES OF OFFSET RESET
0 - 255
0
201
Option (Signal) Not Used
0 FrameLock Option
Frame Lock Setting
0: OFF for PC
1: OFF for AV
2: OFF
3: ON Depending on Input Frequency
4: ON Depending on Input Frequency
0 - 4
4
204
Simulation mode
0 Scaler Enable
0: Off, 1: On
0 - 1
0
205
Spread Spectrum
0 Enable
0: Off, 1: On
0 - 1
1
1 Spread Rate
Default 41
0 - 82
41
2 Spread Frequency
Default 0
0 - 2
0
220
Projector Error Log
0 Warning_Log_1
Latest Error log
0 - 32767
0
: :
:
:
:
49 Warning_Log_50
50th Error log
0 - 32767
0
50 Warning_Log Reset
Log is cleared when the value is set to 10.
0 ~ 10
0
235
Shutter
0 Power ON_OFF Motion
Shutter Warm - up Operation (0: Yes, 1: No)
0 - 1
Initial: 1 / Shipping: 0
1 CMP_TRM
Chattering Detecting Term
0 - 32767
7000
2 OUT_DLY_TRM
Output Term
0 - 32767
15000
3 CMP_CHK_CNT
Count of Information Sync
0 - 15
5
4 OPEN_DLY
Open Output Delay
0 - 63
0
5 CLOSE_DLY
Close Output Delay
0 - 63
0
6 Position Check Time
Position Check Time
1 - 255
30
7 Stop Mode
Shutter Operation in Stop Mode
0:Free, 1:Brake
0 - 1
0
8 Enable Close Cmd
Shutter Close Command
0:Disable, 1:Enable
0 - 1
1
10 Shutter Management Upper Time
180 - 999
480
240
Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
0 - 1
0
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
-
255
2 Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
3 Air Inlet Check Enable
Intake Vent Error Check (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
5 Clog Auto Cooling Enable
Cooling on Clog (0: Disable, 1: Enable)
0 - 1
1
6 Scroll Fail Auto Cooling Enable
Cooling on Scroll error (0: Disable, 1: Enable)
0 - 1
1
8 Filter Counter Remaining Enable
Filter Counter Remaining Function (0: Disable, 1: Enable)
0 - 1
1
13 Filter Stanbdard Limit
Filter life (x100 hour)
0 - 255
Normal filter: 50
Special filter: 10
14 Filter Max Limit
Filter Limit (x100 hour)
0 - 255
Normal filter: 60
Special filter: 15
Summary of Contents for LC-XT6
Page 192: ...192 IC Block Diagrams CXD3548 Gamma IC401 CXA7009 S H IC501 IC531 IC561 IC1501 IC1531 IC1561...
Page 193: ...193 IC Block Diagrams FA5501 PFC IC1601 IC1651 HIN202 RS232C Driver IC3801...
Page 195: ...195 IC Block Diagrams AX11005 Network IC8301 TE7783 I O Expander IC1801...
Page 196: ...196 IC Block Diagrams...
Page 204: ...SPL 8 LC XT6 Exploded Views M01 4 M01 5 Lens shift assembly M01 1 M01 3 M01 2...
Page 209: ...SPL 13 LC XT6 Exploded Views Optical filter LC CS L19 Integrator assembly S06 L11 S06...
Page 211: ...SPL 15 LC XT6 Exploded Views Relay lens OUT assembly L06 S06 S06...
Page 212: ...SPL 16 LC XT6 Exploded Views L08 L07 In the Optical unit L15 L15 L05 L22 L14 L13 L21 L09 L10...
Page 213: ...SPL 17 LC XT6 Exploded Views Optical filters assembly Mirror assembly L16 L16 L18 L17...
Page 214: ...SPL 18 LC XT6 Exploded Views Labels W09 W07 W01 W01 W06 W08 W04 W04 W04 W03 W02 W05...
Page 218: ...SPL 22 LC XT6 Mechanical Pats List...