6 Operation
Installation and Operating Instructions
High Pressure Cleaner, Hot Water, Stationary
HSC1140-INOX Gas
The design of the system distinguishes between two levels of access:
●
Level 1:
Skilled personnel authorized by the system operator to set system
parameters and operation (see Section 6.3.2, System Setup and
Operation for Skilled Personnel):
○
Access to the control and indicator elements inside the cabinet via a
lockable door.
○
Adjustment of the desired operating parameters via the control
elements inside the cabinet for:
–
Operating pressure
–
Water temperature
–
Quantity of water
–
Detergent additive.
○
Control elements (three main switches) on the front of the cabinet
door.
●
Level 2:
Operating personnel for carrying out cleaning work (see Section 6.3.3,
Operation for Operating Personnel) with access for:
○
Control elements (three main switches) on the cabinet door front for
selecting the operating modes:
–
Start - Stop:
On - Off
–
Hot water:
On - Off
–
Detergent:
On - Off
6.3.1
EMERGENCY STOP - switch-off in case of danger
WARNING
In case of electrical accidents, never directly touch persons exposed life-
threatening voltages.
In the event of accidents with persons at life-threatening voltages,
immediately switch off the supply voltage to the high pressure cleaner or
disconnect the power supply cable from the infrastructure mains plug.
Never touch the exposed person who has been involved in an accident
directly. First aiders are also endangered by electric shock if they touch the
person directly, in wet areas or over wet objects.
In extreme emergencies, without touching the injured person, use a
dry garment, wooden slat or other insulating material to separate the
person and power source.
In case of accidents with persons or for accident prevention during system
operation, perform an EMERGENCY STOP switch-off as follows:
If necessary, if persons are still exposed to electric shock, switch off the
power supply to the system via the circuit breaker (building connection)
or disconnect the power supply cable from the mains socket.
Switch off the main switch Start - Stop (1, fig. 6 - 1) on the cabinet door
front (bring it to position 0).