![EHRLE HSC1140-INOX Gas Installation And Operating Instructions Manual Download Page 41](http://html1.mh-extra.com/html/ehrle/hsc1140-inox-gas/hsc1140-inox-gas_installation-and-operating-instructions-manual_2368758041.webp)
300631 • 1/2018 • H.S.
41 of 82
5 Commissioning
Installation and Operating Instructions
High Pressure Cleaner, Hot Water, Stationary
HSC1140-INOX Gas
The following exhaust gas values must be achieved:
Exhaust gas
150 ... 170 °K
differential temperature:
Carbon dioxide content:
10.0 ... 11.0 CO2 in %
Carbon monoxide:
25 ... 50 ppm
Soot number:
0 according to Bacharach scale
Exhaust gas loss:
8 ... 11 %
If the above limit values are not complied with, the gas burner must be
adjusted by trained and qualified personnel.