
®
A NORDSON COMPANY
Ultra TT User's Guide
Version 1.2
4.1.2.1
Configuring Toggle
1.
At the Setup screen, tap "Setup" at the upper left-hand corner
of the screen.
2.
Select "Configuration" to configure
the
toggle bit (the internal I/O instruction to
turn on the solenoid for the toggle
bracket).
3.
Enter the desired I/O bit to turn on the
air solenoid i.e. will cause the toggle
bracket to shift. Select Output Bit 7
for EXT_SOLENOID_B or Output Bit 6
for EXT_SOLENOID_A.
31
Note:
The Ultra TT provides two external outputs to drive air solenoids. Each solenoid driver
has a maximum power rating of 5 Watts. Select desired assertion level. To test the toggle
bit you can press the down button to assert the toggle bit and press the up button to
negate the toggle bit.
The EXT_SOLENOID_A and EXT_SOLENOID_B
connections are made on the Discrete I/O
terminal block located on the rear panel.
•
24VDC+ is supplied on Pin 14
•
EXT_SOLENOID_A is supplied on Pin 13
•
EXT_SOLENOID_B is supplied on Pin 12
•
GND is supplied on Pin 11
4.1.2
Toggle Valve
If a Toggle bracket is selected, you will also need to teach an offset for
the toggle valve. Follow the instructions in Section 4.1.1.1 to teach offset
for the Toggle Valve. However, prior to teaching the offset, the toggle
valve bit configuration must first be completed.