Ultra TT User's Guide
Version 1.2
2
Setup
2.1
Preparing the Work Area
Place the Ultra TT system on a
stable
table or bench. The Ultra TT needs enough space behind
the machine (at least 250mm) to allow for the tooling to move to its home position. This space
also ensures the fan duct on the back of the machine is not obstructed and thereby allows for air-
cooling of the internal electronics.
Allow enough room to place fluid reservoir pressure tank beside the machine. Fluid cartridges may
be mounted to the uprights using the M8 T-Slots on either side of the Ultra TT.
2.2
Main Air and Electrical
It is important that you have
dry, clean filtered air that is aerosol free
to prevent problems with the
pneumatic system of your new Ultra TT system. Input air should not be more than 100 psi. If you
have any doubts about your air supply, you should purchase one of the two filter regulator sets
listed below.
Main air input is located immediately to the left of the Fan Duct on the back panel of the machine
and accepts 6mm diameter tubing. Simply push the 6mm tubing into the push-fit connector.
Each unit is shipped with two power cords. Plug the appropriate power cord into the three-prong
power cord slot located on the back of the machine next to the main power circuit breaker. The
machine is equipped with a self-regulating power supply and will accept 100VAC ~ /- 10%,
50 ~ 60 Hz input voltage.
17
2000F755TT Five-micron filter regulator
Order this if you do not have dry clean
filtered factory air supply
2000F756TT Five-micron filter regulator
with coalescing filter to remove
aerosols from air supply
Plant air, 125 psi maximum to
regulator. Output from regulator
should be a minimum of 80 psi,
maximum of 100 psi.
Air input
hose