background image

*NOTE: G WILL ENERGIZE IMMEDIATELY WITH 1

ST

 STAGE  IF DIP SWITCH #5 IS SET TO 

“ELECTRIC”.  IF SET TO THE DEFAULT OF “GAS”, G WILL ENERGIZE AFTER 90 SECONDS.

EQ

UIP

ME

NT

W2

*O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

O/B

Y1

Y2

*G

W1

EH

EQ

UIP

ME

NT

W2

O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

*O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

*O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

*O/B

Y1

Y2

G

W1

EH

EQ

UIP

ME

NT

W2

O/B

Y1

Y2

G

W1

EH

COOLING

1

ST

 STAGE

2

ND

 STAGE

ALL TYPES (HP & GE)

CUT OUT:

 

LO TEMP 

+4

CUT IN:

 

LO TEMP 

+10

CUT OUT:

 

LO TEMP

1

ST

 STAGE STARTS WITH ANY CALL 

FROM A THERMOSTAT FOR COOL

· 

2

ND

 STAGE OCCURS AFTER 8 MINUTES OF 1

ST

 STAGE, IF 

SUPPLY TEMP WARMER THAN 

LO TEMP 

+ 10

°

· 

EQUIPMENT WILL RETURN TO 1

ST

 STAGE IF SUPPLY TEMP IS 

COOLER THAN 

LO TEMP

 + 4

°

 (2

ND

 STAGE WILL NOT RE-

ENERGIZE UNTIL AFTER 3 MINUTES “OFF TIME”)

· 

IF SUPPLY TEMP IS COOLER THAN 

LO TEMP

 (SEE ADJUST 

LIMITS) FAN WILL RUN BUT Y1 WILL DE-ENERGIZE FOR 3 

MINUTES & UNTIL SUPPLY TEMP IS WARMER THAN 

LO TEMP 

(DEFAULT = 48

°

F)

1

ST

 STAGE

2

ND

 STAGE

CUT OUT:

 

HI TEMP 

– 10

CUT IN:

 

HI TEMP

 

– 25

CUT OUT:

 

HI TEMP

HEATING

GAS / ELECTRIC

1

ST

 STAGE STARTS WITH ANY CALL 

FROM A THERMOSTAT FOR HEAT

· 

2

ND

 STAGE OCCURS AFTER 8 MINUTES OF 1

ST

 STAGE, IF 

SUPPLY TEMP COOLER THAN 

HI TEMP

 

– 25

°

· 

EQUIPMENT WILL RETURN TO 1

ST

 STAGE IF SUPPLY TEMP IS 

WARMER THAN 

HI TEMP

 – 10

°

 (2

ND

 STAGE WILL NOT RE-

ENERGIZE UNTIL AFTER 3 MINUTES “OFF TIME”)

· 

IF SUPPLY TEMP IS WARMER THAN 

HI TEMP

 (SEE ADJUST 

LIMITS) FAN WILL RUN BUT W1 WILL DE-ENERGIZE FOR 3 

MINUTES AND UNTIL SUPPLY TEMP IS COOLER THAN 

HI TEMP

 

(DEFAULT = 135

°

F)

8 MIN UNTIL 2

ND

 

8 MIN UNTIL 2

ND

 

*NOTE: O/B WILL ALSO ENERGIZE IF DIP SWITCH #2 IS SET TO “B”

1

ST

 STAGE

2

ND

 STAGE

CUT OUT:

 

HI TEMP 

– 5

CUT IN:

 

HI TEMP

 

– 15

CUT OUT:

 

HI TEMP

HEATING

HEAT PUMP

1

ST

 STAGE STARTS WITH ANY CALL 

FROM A THERMOSTAT FOR HEAT

· 

2

ND

 STAGE OCCURS AFTER 4 MINUTES OF 1

ST

 STAGE, IF 

SUPPLY TEMP COOLER THAN 

HI TEMP

 

– 15

°

· 

EQUIPMENT WILL RETURN TO 1

ST

 STAGE IF SUPPLY TEMP 

IS WARMER THAN 

HI TEMP

 – 5

°

 (2

ND

 STAGE WILL NOT RE-

ENERGIZE UNTIL AFTER 3 MINUTES “OFF TIME”)

· 

IF SUPPLY TEMP IS WARMER THAN 

HI TEMP

 (SEE ADJUST 

LIMITS) FAN WILL RUN BUT Y1 WILL DE-ENERGIZE FOR 3 

MINUTES AND UNTIL SUPPLY TEMP IS COOLER THAN 

HI TEMP

 

(DEFAULT = 120

°

F)

4 MIN UNTIL 2

ND

 

*NOTE: O/B WILL ALSO ENERGIZE FOR HEAT PUMP IF DIP SWITCH #2 IS SET TO “O”

AUXILIARY 

CUT IN: < 90

DUAL FUEL

NORMAL

CUT OUT: > 100

2 MIN UNTIL AUXILIARY 

· 

AUXILIARY HEAT OCCURS AFTER TWO 

MINUTES 2

ND

 STAGE (6 MINUTES 

TOTAL) IF SUPPLY TEMP COOLER 

THAN AUX HEAT CUT IN (90

°

 

DEFAULT) [ADJUST: 90 TO 94]

· 

NORMAL: EQUIPMENT WILL RETURN 

TO 2

ND 

STAGE IF SUPPLY TEMP IS 

WARMER THAN 100

°

 

· 

DUAL FUEL: EQUIPMENT WILL CONTINUE IN DUAL FUEL UNTIL CALL(S) SATISFIED.  HI TEMP LIMIT WILL BE 

THE GAS/ELECT “HI LIMIT”

 

(TEMPORARILY SWITCH DIP SWITCH #1 TO GAS/ELECT TO ADJUST DUAL FUEL “HI LIMIT”)

12

(6 MIN AFTER 1

ST

 STAGE)

Summary of Contents for SmartZone ZS2X-2.0

Page 1: ...ONE 4X ZS4X 2 0 8E HI TEMP LO TEMP SUPPLY PURGE DELAY ECO THERMOSTATS HEAT PUMP OR GAS ELECTRIC EASY TO READ DISPLAY LEDs SHOW HEAT COOL CALLS NO VOLTMETER REQUIRED SCREWLESS WIRING TERMINALS FRESH AI...

Page 2: ...STAGE HEAT OR REVERSING VALVE ORANGE 10 AMP 24VAC CONTACT RATING 40VA POWER CLOSE SPRING OPEN DAMPERS 10VA POWER OPEN SPRING CLOSE DAMPERS 10VA POWER OPEN POWER CLOSE DAMPERS 3VA LABEL DESCRIPTION LE...

Page 3: ...DED BY ANY ADDITIONAL PRESSURE RELIEF q REFER TO DUCT DESIGN BYPASS PAGE 3 4 q CALCULATE MINIMUM 24VAC TRANSFORMER VA CAPACITY PAGE 5 q CHECK PRIMARY AND SECONDARY VOLTAGE FOR ZONING TRANSFORMER MAKE...

Page 4: ...E CFM CFM ROUND CFM CHART BYPASS PRESSURE RELIEF BYPASS SIZING SELECT A DAMPER SIZE WITH A MAX CFM GREATER THAN THE CFM NEEDED TO BYPASS USE THE FORMULA BELOW TO CALCULATE CFM NEEDED TO BYPASS AND THE...

Page 5: ...E SPEED EQUIPMENT AVOID CREATING MORE THAN THREE ZONES WITH NO ZONE SMALLER THAN 20 OF THE TOTAL EQUIPMENT CFM CAPACITY RETURN AIR UNDERSIZED RETURN AIR DUCTS REGISTERS CAN RESULT IN PROBLEMS DUE TO I...

Page 6: ...DETAILS IN ZONING GUIDE ENERGIZES FAN AFTER 90 SECOND DELAY WITH HEATING 2ND STAGE ACTIVE NORMAL AUX HEAT COMPRESSOR ELECTRIC HEAT STRIPS REVERSE VALVE ON IN COOLING EQUIPMENT GAS ELECTRIC STANDARD HE...

Page 7: ...TRIC OR DUAL FUEL AFTER COIL BEFORE BLOWER SAS INCLUDED ALWAYS TO THE LEFT EXCEPT FOR 5 THROUGH 20 ZONES DETAILS PAGE 14 ENERGIZES FAN IMMEDIATELY WITH HEATING 2ND STAGE ENERGIZES ONLY IF MORE THAN ON...

Page 8: ...ED NOTE ALWAYS DISCONNECT POWER TO SMARTZONE WHILE MAKING ANY WIRING CHANGES DO NOT USE EQUIPMENT TRANSFORMER 24 VAC COMMON TRANSFORMER PRIMARY INSTALLATION DO NOT CONNECT POWER UNTIL ALL WIRING IS CO...

Page 9: ...G 24VAC R HEATING EH O B PC PO COM POWER OPEN POWER CLOSE 24 VAC 2 3 VA SPRING OPEN POWER CLOSE 24 VAC 6 10 VA DAMPERS SUPPLY TEMP EQUIPMENT REQUIRES SEPARATE TRANSFORMERS FOR HEAT AND COOL NOTE RELAY...

Page 10: ...2 STAGE GAS ELECTRIC H2 2 STAGE HEAT PUMP 4 HI TEMP LO TEMP SUPPLY PURGE DELAY ECO ZONE PRESS RELEASE THE UP ARROW BUTTON WHEN THE DISPLAY IS SHOWING SUPPLY TEMPERATURE THE HI TEMP INDICATOR WILL FLA...

Page 11: ...LS OTHER ZONES WILL ONLY OPEN AND CLOSE DAMPERS AS NEEDED FLASH ON SE SETTING CHANGES STORED IN MEMORY THIS WILL SHOW UP AFTER ADJUSTING ANY SETTING INCLUDING STAT TYPE LIMIT TEMPERATURES AND FRESH AI...

Page 12: ...E SMARTZONE SYSTEM WILL BE LOCKED INTO EMERGENCY HEAT THE COMPRESSOR WILL NOT ENERGIZE AND ONLY HEATING CALLS WILL BE RECOGNIZED FROM ANY ZONE OTHER THAN ZONE 1 ONLY W1 EH AND G WILL BE ALLOWED TO ENE...

Page 13: ...10 2ND STAGE WILL NOT RE ENERGIZE UNTIL AFTER 3 MINUTES OFF TIME IF SUPPLY TEMP IS WARMER THAN HI TEMP SEE ADJUST LIMITS FAN WILL RUN BUT W1 WILL DE ENERGIZE FOR 3 MINUTES AND UNTIL SUPPLY TEMP IS CO...

Page 14: ...LAY ECO 2 3 PRESS TO SELECT THE OF MINUTES PER HOUR FOR FRESH AIR RUN TIME IN 5 MINUTE INCREMENTS PRESS STAT TYPE BUTTON TO SELECT ZONE 4 PRESS UP BUTTON TO SELECT FA PRESS STAT TYPE AGAIN 4 0 HI TEMP...

Page 15: ...HE PRIMARY AND SECONDARY POLARITY MUST BE THE SAME ON ALL SMARTZONE 4X BOARDS 24VAC 24VAC FIRMWARE VERSION SHOWN ON DISPLAY AFTER RESET OR POWER UP CONNECT EQUIPMENT SAS ONLY TO MAIN ZONES 1 4 SMARTZO...

Page 16: ...FAN SPEED WIRING POWER ETC ANY PROBLEM ASSOCIATED WITH THE EQUIPMENT A INCOMPATIBLE POWER STEALING NO COMMON B DEFECTIVE THERMOSTAT C WIRING DEFECT D STAT TYPE SETUP HEAT PUMP ONLY A ACTUATOR FAILURE...

Reviews: