7.11 Terminal assignment of the analogue inputs of temperature sensors
Controller
Type
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 6
Sensor 7
Sensor 8
Sensor 9
Sensor 10
Terminal
No.
Z11/Z12
Z21/Z22
Z31/Z32
Z41/Z42
Z51/Z52
Z61/Z62
Z71/Z72
Z81/Z82
Z91/Z92
Z01/02
UA 410 L
Rx.1
Rx.2
Rx.3
Rx.4
Rx.5
Rx.6
Rx.7
Rx.8
Rx.9
Rx.0
Warning - hazardous electrical voltage!
Connecting mains power to the analogue inputs will leadto
the destruction of the controller!
Malfunctions due to interference sources!
All leads running to and from the case controller must be
shielded (cable type: LiYCY)! No shielding is required on sensor leads when installed exclusively
inside the refrigerated display case and when external interference (for example from parallel power
wires) is not to be expected (see operating instruction "Basics and General Safety and Connection
Instructions"). As a general rule, care should be taken to ensure that signal leads and leads carrying a
supply voltage are routed through separate cable channels.The case controller analogue inputs
are
only
approved for the connection of temperature sensors as named in
Connecting a supply voltage to the analogue inputs will lead to the destruction of the case controller!