THE FOLLOWING CONDITIONS 

ARE NOT A FAULT

Phenomenon

Reason and Handling Method

Exhaust white Smoke

INDOOR 

temperature is too low. The exhausted 

smoke encountered the cold air and then is 

condensing into a white mist.

Flow rate of generated 

hot water is too small to 

achieve requested water 

temperature

Hot water flow is too low to ignite the water heater. 

The water heater will not turn on if the flow is too 

low and then the water will become cold. Raise the 

flow rate higher to activate the heater.

Can’t supply high 

enough temperature in 

winter

The incoming water temperature is very low and 

the water adjustment knob is already turned to 

maximum. The set temperature may be more 

than the heating capacity allows. Please adjust 

the flow lower to allow the water to heat to higher 

temperatures.

Water is too hot during 

the summer

Incoming water temperature is too high and the 

incoming flow is too low. It may cause the hot 

water to be too hot. Please adjust the flow to be 

more to lower the temperature.

The water heater turns 

off after 40 minutes

In order to prevent hypoxia, some models have a 

40 minute timer protection function. When you 

continuously use the water heater for 40 minutes, 

it will turn off. Please turn off the tap and restart.

Close the hot water 

valve, but the fan does 

not stop immediately

The fan has a delay in the shutdown function in 

order to completely clean the water heater exhaust 

to ensure the safety of users.

Open the hot water 

valve, but hot 

water does not flow 

immediately

There is a distance from the water heater to the 

outlet, so the cold water in the line must flow out 

before the hot water reaches your outlet. The 

farther the distance from the water heater, the 

more time it takes to receive hot water.

There is always some 

water from the drain 

valve

This is because the inlet water pressure is too high 

and the drain valve will work to release the high 

pressure. Try to reduce the inlet water pressure by 

turning down the gate valve or the ball valve until 

water leakage stops.

Summary of Contents for 6.5GB BUILDER Series

Page 1: ...ER SERIES WHOLE HOME TANKLESS HOT WATER HEATER INSTALLATION USE AND CARE INSTRUCTIONS 100 F INDOOR MANUAL Wash Down Apartment Condos Tiny House Office Cabins Mid Size Home Whole Home Town Home 6 5GB L...

Page 2: ...causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances WHAT TO DO IF YOU SMELL GAS Do not...

Page 3: ...our un fonc onnement s curitaire du chauffe eau la soupape de d charge ne doit pas tre enlev e ou bouch e UTILISATION L INT RIEUR SEULEMENT Eccotemp Systems LLC 315 A Industrial Road Summerville SC 29...

Page 4: ...on on If You Need Service Do not destroy this manual Please read carefully and keep in a safe place for future reference Recognize this symbol as an indication of Important Safety Information Californ...

Page 5: ...many important safety messages in this manual and on your water heater Always read and obey all safety messages This is the safety alert symbol Recognize this symbol as an indication of Important Safe...

Page 6: ...ding flue terminal inspection DANGER PROPERLY INSTALL WATER HEATER Installation DO NOT Install water heater where flammable products will be stored or used unless the main burner flame Is at least 18...

Page 7: ...temperature on remote control The remote control was set at 110 F before it was shipped from the factory The illustration to the bottom left illustrates the Remote Control and how to adjust the water...

Page 8: ...ified for any other fuel type LPG water heaters should not be installed below grade for example in a basement if such installation is prohibited by federal state and or local laws rules regulations or...

Page 9: ...water heater Use this water heater only for its intended purpose as described in this Use and Care Manual Be sure your water heater is properly installed in accordance with local codes and the provide...

Page 10: ...heater should be properly grounded The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater must be installed vertica...

Page 11: ...ents are released that will shorten the life of any gas burning appliance Propellants from common spray cans or gas leaks from A C and refrigeration equipment are highly corrosive after passing throug...

Page 12: ...sidewalk or paved driveway that is located between two single family dwellings This water heater is strictly forbidden to be installed outdoors and in the bathroom The water heater shall not be instal...

Page 13: ...nd gas to make sure the outlet water temperature is consistent Low start up water pressure Flame out protection if the water heater flames out suddenly it will cut off the gas automatically to make su...

Page 14: ...pe work must be used between the outlet of the water heater and first outlet Shown below The hot water line should be insulated with armaflex or similar pipe insulation When the installation is comple...

Page 15: ...he hot water system the temperature rises continuously and the volume of water expands If the system is equipped with an expansion tank or a flexible connection bellows can absorb a part of the expans...

Page 16: ...a gas leak test either by applying soapy water to all gas fittings and observing for bubbles or by using a gas leak detection device PLEASE NOTE 6 5GB IS FOR INDOOR PERMANENT INSTALLATIONS ONLY THIS M...

Page 17: ...can be installed horizontally or vertically but it cannot make pressure outlet facing upwards otherwise it cannot work normally It is forbidden to block its outlet The dirt will directly affect the no...

Page 18: ...ed off if necessary If the cord supplied with this appliance must be replaced it must be replaced with the correct appliance wiring material supplied by the Manufacturer When servicing or replacing pa...

Page 19: ...R YOUR SAFETY READ BEFORE OPERATING Check the GAS and WATER CONNECTIONS for leaks before startup for the first time Open the main gas supply valve to the unit using only your hand to avoid any spark N...

Page 20: ...lose the gas valve When the power is reset the water heater with the remote control can be started by the remote control and the water heater without the remote control can be started after re opening...

Page 21: ...ert the filter back into the cold water inlet Securely screw the drain plugs back into place Hand tighten only Remove by turning counter clockwise and then clean and replace 1 Turn off the water inlet...

Page 22: ...lve fully open 3 Is the filter on cold water inlet clean 4 Are the fixtures clean of debris and obstructions Fluctuation in hot water temperature 1 Is the filter on cold water inlet clean 2 Is the gas...

Page 23: ...heater After restarting and it is not operating normally please notify the after sales service staff maintenance Error Code Fault description and handling method E0 Water temperature probe fault E1 Fl...

Page 24: ...higher temperatures Water is too hot during the summer Incoming water temperature is too high and the incoming flow is too low It may cause the hot water to be too hot Please adjust the flow to be mo...

Page 25: ...rt Eccotemp com Shop Online www Eccotemp com 1 Service shall be carried out only by authorized personnel and the appliance shall not be modified 2 The appliance must be installed commissioned and serv...

Page 26: ...nt or refund will be issued Any return for refund must be approved by Eccotemp s Customer Service team prior to shipping the Product back to Eccotemp Please refer to Returning Your Product For Repair...

Page 27: ...for any expenses arising from labor services including but not limited to installa tion or removal services due to a warranty claim 4 A repair replacement or refund will not be provided if the Product...

Page 28: ...315 A Industrial Road Summerville SC 29483 1 866 356 1992 Eccotemp 2022 All Rights Reserved Printing Version 1 3...

Reviews: