PLEASE NOTE: 6.5GB IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT
TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
EN
G
LIS
H
18
Support:
Support.Eccotemp.com
Shop Online:
www.Eccotemp.com
• The water heater must be electrically grounded. Do not attach the ground wire to either the gas or
water piping.
• The water heater requires an AC 120V 60Hz.
• The weather-proof power point should be no more than 3FT from the base of the water heater for easy
access.
•
Install a power switch so that the electrical power can be switched off if necessary.
• If the cord supplied with this appliance must be replaced, it must be replaced with the correct appliance
wiring material supplied by the Manufacturer.
• When servicing or replacing parts within the water heater, label all wires prior to disconnection to
facilitate an easy and error free reconnection. Verify proper operation after servicing.
CONNECTING THE ELECTRIC
WARNING! Turn off the electric power to the water heater and manual gas valve located on
the outside of the unit before beginning gas connection. Confirm the position of the gas inlet. Do
not connect water line to gas inlet.
WARNING! Conversion of this unit from natural gas to propane (LPG) or propane (LPG) to
natural gas cannot be done in the field. Contact your supplier to get the correct unit for your gas
type.