• Mark the wall with a dark mark, then drill three holes with a diameter of 8mm and a depth of 2
3/4 inch, then insert three 1/4 x 2 inch expansion screws into the hole and tighten the screws with
a wrench.
• Hang up the water heater, screw on the 1/4 inch nut and fix the heater to the wall.
• Incorrect installation of the heater will affect the normal use of the water heater
WATER HEATER INSTALLATION
TECHNICAL DATA AND DIMENSIONS
PLUMBING NOTES
• When connecting the hot water supply to the fixtures of the property a minimum of 6.5 FT
of pipe work must be used between the outlet of the water heater and first outlet.
(Shown below)
• The hot water line should be
insulated with armaflex or similar
pipe insulation.
• When the installation is
completed the temperature is to be
tested at the outlet to confirm the
water temperature does not exceed
the required 122°f (50°c) setting.
• Water pipe size is nominal 1/2
inch from hot water outlet to the
first outlet.
• Gas pipe size in nominal 3/4 inch.
100
°
F
6.5 FT
MODEL:
6.5GB
ING
ILP
GAS INPUT
MIN:
17
,000
MAX:170,000
MIN:
17
,000
MAX:170,000
AVAILBALE CERTIFICATE
CSA,DOE
FLOW RATE(45°F) TEMP RISE
6.34 GPM
PRODUCT DIMENSIONS(INCHES)
26.2 x 17.1 x 7.3
PACAKAGE DIMENSIONS(INCHES)
33.1 x 20.9 x 10
NET WEIGHT(LBS)
39.3
GROSS WEIGHT(LBS)
4
5
INSTALL TYPE
indoor, wall hung
VENTING TYPE
category III type B
IGNITION
electric
WATER PRESSURE(PSI)
15 - 150
GAS INLET PRESSURE W.C (KPA)
min: 3.5(.87), max: 10.5(2.61)
min: 8(1.99), max: 13(3.23)
ACTIVATION FLOW RATE(GPM)
.5
5
CONNECTION SIZES
3/4” NPT
RATED POWER SUPPLY(WATTS /
AMPS)
43 / 0.6