WX2NB Manual v.1.0
Page 29 / 40
6.4.3.
Power loss
One of device additional options is monitoring of power supply voltage. As short
voltage drop may follows at some facilities, it is possible to avoid reporting by
entering time after which information will be sent.
Value of this parameter means that voltage drop shall follow within this determined
time so that device recognizes it as real voltage drop and that information might be
sent.
6.4.4.
Low DC power voltage
When the supply voltage falls below the defined threshold in this field, POWER loss
event is generated. The minimum value possible to set is 8V, maximum 13V.
Information about the end of POWER failure is sent if the voltage increase by 0.5V
from the defined value.
6.5.
LINK CONTROL
These options enable the automatic response of the device when the connection to
the monitoring station is broken. This applies to situations where the device has lost
communication with the Wi-Fi network or when transmission is impossible.
6.5.1.
Wi-Fi
Activating this function (checking the [Enable] box) provides access to parameters
that define the device's reaction when Wi-Fi connection is lost.