7.4.3.
SMS On / SMS Off
In this column you define signals that may be reported at monitoring station with
SMS messages – when there is no connection with server over GPRS. There is
possibility to send information on alarms (input state change from rest to action
status) and on returns of input state from action to rest (normalization).
To transmit any signal you should only click it (proper square on your right).
Click on [Clear] button to remove all marked signals.
Click on [Invert] button to change markings to contrary.
7.4.4.
Skip initial state
This option allow for locking of sending of information on status of active inputs at
power connection. Information on inputs will be sent to server after the first change
from inactive to active status.
For the events “Power” and “Battery” no selection “Skip initial state” will cause
sending information about the power supply / battery on boot device regardless of
the power supply / battery state.
7.4.5.
Power loss
One of device additional options is monitoring of power supply voltage. As short
voltage drop may follows at some facilities, it is possible to avoid reporting by
entering time after which information will be sent.
Value of this parameter means that voltage drop shall follow within this determined
time so that device recognizes it as real voltage drop and that information might be
sent.