EPX400-xC – Manual
Page 53 / 73
8.7.1.
Serial port settings
The selected parameters shall correspond to RS-232 port settings in device which will
be connected to the transmitter. Available parameters are shown in the table below:
Parameter
Value
Baud rate (bits/sec)
1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200
Data bits
8
Parity
None, Even, Odd
Stop bits
1, 2
Flow control
None, RTS, CTS, RTS/CTS
If RS232 checkbox will not be enabled, data to the Event monitor will be sent on
device’s serial port. With this setting, GD-PROG cable can be used to observe device
state using GPRS transmitters configurator application and Monitor option described
in point 8.11.
8.7.2.
Buffer flushing
Data received from connected device are stored in transmitter buffer. Buffer capacity
is 511 bytes. Define criteria that meeting shall mean data transmission to monitoring
system transmitter. The following options are available:
- After receiving defined ASCII character
- After expiry of defined time
- After receiving defined amount of characters