EPX400-xC – Manual
Page 40 / 73
8.3.2.1.
Partition arming input
Using this, partition arming input can be selected. To selected input, arming device
(remote controller receiver output or electronic keyboard NO/NC output for instance)
is connected. When this input is armed, partition is armed (after Exit Time, see
below). When arming input is disarmed, partition is disarmed.
8.3.2.2.
Inputs assigned to partitions
Assigning input to partition means that it is monitored only when partition to which
input belongs is armed. Input can be assigned up to one partition. Arming inputs can
not be assigned to any partition. If input is not assigned to any partition, it acts as 24
hours input – it is monitored regardless of partitions state.
8.3.2.3.
Delayed inputs
Here, delayed inputs can be selected. Delayed input switches on associated output,
ie. generates alarm, after expiry of Entry time, but only when partition to which input
belongs will not be disarmed before Entry time period.
8.3.2.4.
Exit time
Partition exit time. Partition inputs will be monitored when this configured time
elapses after partition input had been armed.
8.3.2.5.
Entry time
Time after which alarm will be generated after delayed input had been armed and
partition to which delayed input belongs will not be disarmed.