GB
5.2 NOT INTENDED USE
All uses not specifically mentioned in 5.1 are generally
banned; in particular, the fluid must not contain aggressive
or explosive additives, mixtures of mineral oils and/or solid
or fibrous particles. The pump should not be used for
pumping flammable or explosive media, or in an explosive
atmosphere. To avoid formation of condensation in the
pump, fluid temperature must be higher or equal to the
ambient temperature.
6. TECHNICAL AND BUILDING FEATURES
6.1 TECHNICAL DATA
Ego (T) (C) slim
Pump type
40-80 40-120 40-180 50-80 50-120 50-180 65-80 65-120 65-180 80-80 80-120 80-180
Power P
1
[W]
270
480
680
370
560
800
560
800
800
Rated current I
n
[A]
1,2
2,3
2,9
1,7
2,5
3,7
2,5
3,7
3,7
Power Supply
1~230V – 50/60Hz
Motor protection
External protection is not necessary
Protection class
IP44
Insulation class
F
Relative humidity
Max 95%
Ambient temperature
0-40°C
Medium temperature
min -10° max 110° C
System pressure
Up to 1 MPa (10 bar)
6.2 LIMITS OF USE
The minimum pressure at suction shall be:
- 0.05 bar for medium at 50°C
- 0.80 bar for medium at 80°C
- 1.40 bar for medium at 110°C
Ambient and medium temperature:
Ambient
Temperature [°C]
Medium Temperature
min. [°C]
max. [°C]
Up to 25°C
-10
110
30°C
-10
100
35°C
-10
90
40°C
-10
80
Working outside of recommended conditions
can shorten life time and nullify the warranty
7. INSTALLATION, DISMANTLING
AND TRANSPORT
7.1 GENERAL ARRANGEMENT FOR INSTALLATION
• The pump must be mounted with electromotor shaft
in horizontal position (fig. 3.1). Allowed and forbidden
positions are shown in fig. 3.2
• The arrow on pump plate shows direction of medium
flow
• If there is not enough space for electric connection,
control box can be rotated so that the connector is in
a horizontal position
• A position with the electrical connector vertically above
the motor is not allowed (see fig 3.3c)
• Prior to rotating the electric motor part, close the shut-off
valves on the pressure and suction side of the pump and
unscrew the screws (Fig. 3.3). Turn the electric motor
part as shown in Fig. 3.3a or 3.3b.
7.2 DISMANTLING
In order to handle and dismantle the electropump you should:
a) Take off the power supply.
b) Lift the electropump with suitable means according to
its weight and dimensions
7.4. TRANSPORT
The electropump is packed in a carton or, depending on
its weight and dimensions, it is fixed on a wooden pallet;
however, transport does not present many difficulties.
In any case, check the total weight imprinted on the box.
8. ELECTRICAL CONNECTION
8.1. PROTECTIVE DEVICES
• ALL THE CONNECTIONS MUST BE EXECUTED
ACCORDING TO THE LAW BY A QUALIFIED TECHNICIAN.
• ALL THE ELECTRICAL MASSES MUST BE CONNECTED
TO THE EARTH OF THE PLANT ACCORDING TO
THE ELECTRICAL STANDARDS IN FORCE IN YOUR
COUNTRY: THE INSTALLER SHALL BE THE SOLE
RESPONSIBLE FOR IT.
• FOR THE THREE-PHASE AND SINGLE-PHASE TYPES,
WE RECOMMEND INSTALLING A HIGH SENSITIVE
DIFFERENTIAL SWITCH (0.03 A).
After installing the unit check again the feeding cable
following the CABLE CONNECTION instructions and
connect it to the control panel that must be fitted, according
to the actual rules, with: