Passive Point Source
Application Guide
1
2
8
5
3
6
10
11
12
4
9
7
1.
Input Signal Indicators
– A set of five indicators show “Sig”, “-12”, “0dBu”, “+6” and “+12” and
“Clip (mute)” for each of the DSP inputs “A” “B” “C” “D”. The signal present Indicators operate at
approximately –40 dBu. The Clip/mute Indicators warn the user of input overload and operate
at 1dB before clip. This indicator also shows a muted input.
2.
Power Switch
– Applies mains power to the device. If the device has entered Sleep mode, it
may be woken up again either from the EAW Resolution software application, or by switching
this switch off, then on again.
3.
Menu Buttons
– There are three buttons to determine which section of the device to view or
edit. The <OUTPUT> button displays pages of parameters associated with a particular output
channel. The <INPUT> button displays pages of parameters associated with a particular input
socket or input DSP channel. Pressing <INPUT> or <OUTPUT> buttons repeatedly will scroll
through the inputs/outputs of the device. After the last channel, navigation returns to the Home
screen. The <UTILITY> button displays pages of miscellaneous parameters not associated with
any particular channel. Whilst in Edit mode, one of these three buttons will be illuminated. They
are mutually exclusive – pressing one of the buttons will deselect any others that are active.
Pressing Utils will escape back to the Home screen.
4.
Page Selection Buttons
– When one of the buttons <INPUT>, <OUTPUT> or <UTILITY> is
illuminated, the up <P> and down <Q> arrows will also illuminate, informing the user that these
buttons may be used to scroll through the various pages of parameters that may be viewed and
edited. The <ENTER> button is used to confirm an operation. It will illuminate when the user
is being invited to press it. It will flash when warning the user that pressing this button will
activate an important function.
5.
Graphical Display
– This will show the Home screen; a useful overview of channel allocation.
On most pages the currently selected channel and parameter information is displayed on the
upper part of the screen and the parameter value on the lower part of the screen; this can also
optimize the viewing angle.
6.
Status Indicators
– The “OVERLAY” indicator indicator is not currently used. The <DANTE
AUDIO> indicator illuminates when one or more of the inputs is using a Dante source. The
“ONLINE” indicator has three states: Off– the unit is offline and not connected to a computer or
network. Flashing– the unit is searching for an IP address; if the unit does not find an IP address
the unit will assign itself an IP address automatically and the indicator will stop flashing. On– the
unit is online and connected with software. IP settings can be viewed or changed within the