![Eaton PowerXL DG1 Communications Manual Download Page 183](http://html1.mh-extra.com/html/eaton/powerxl-dg1/powerxl-dg1_communications-manual_3902271183.webp)
160
Appendix A—Parameter ID list
POWERXL DG1 SERIES VFD
MN040010EN—September 2016 www.eaton.com
Menu
Item No.
Modbus
Register
Profibus
PNU
Profibus
PNU
SubIndex
EtherNet/
IP Class
EtherNet/
IP Instance
EtherNet/
IP Attribute
DeviceNET
Class
DeviceNET
Instance
DeviceNET
Attribute
Parameter Description
P18.4.10
2442
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Aux Pump Delay
P18.5.1
2449
NA
NA
NA
NA
NA
NA
NA
NA
Number of Drives
P18.5.2
2284
NA
NA
165
1
61
NA
NA
NA
Regulation Source
P18.5.3
2285
NA
NA
165
1
62
NA
NA
NA
Recovery Method
P18.5.4
2286
NA
NA
165
1
63
NA
NA
NA
Callback Source
P18.5.5
2311
NA
NA
165
1
80
NA
NA
NA
Add/Remove Drive Selection
P18.5.6
2280
NA
NA
165
1
58
NA
NA
NA
Run Time Enable
P18.5.7
2281
NA
NA
165
1
59
NA
NA
NA
Run Time Limit
P18.5.8
2283
NA
NA
165
1
60
NA
NA
NA
Run Time Reset
P18.5.9
2473
NA
NA
NA
NA
NA
NA
NA
NA
Master Drive Mode
P18.5.10
2474
NA
NA
NA
NA
NA
NA
NA
NA
Master Fixed Speed
P18.5.11
2475
NA
NA
NA
NA
NA
NA
NA
NA
Master Fixed Speed Delay
P18.6.1
2406
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Detection
Method
P18.6.2
2407
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Level
P18.6.3
2408
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Time
P18.6.4
2409
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Frequency
P18.6.5
2410
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Response
P18.6.6
2411
NA
NA
NA
NA
NA
NA
NA
NA
Pipe Fill Loss Attempts
P18.6.7
2428
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Enable
P18.6.8
2429
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Level
P18.6.9
2431
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Frequency
P18.6.10
2432
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Delay Time
P18.6.11
2433
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Loss of Prime
Level
P18.6.12
2434
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Level 2
P18.6.13
2436
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Frequency 2
P18.6.14
2437
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Delay Time 2
P18.6.15
2438
NA
NA
NA
NA
NA
NA
NA
NA
Prime Pump Loss of Prime
Level 2
P19.1
491
NA
NA
161
1
146
179
1
1
Interval 1 On Time
P19.2
493
NA
NA
161
1
147
179
1
2
Interval 1 Off Time
P19.3
517
3122
0
161
1
148
179
1
3
Interval 1 From Day
P19.4
518
3123
0
161
1
149
179
1
4
Interval 1 To Day
P19.5
519
3124
0
161
1
150
179
1
5
Interval 1 Channel
P19.6
495
NA
NA
161
1
151
179
1
6
Interval 2 On Time
P19.7
497
NA
NA
161
1
152
179
1
7
Interval 2 Off Time
P19.8
520
3122
1
161
1
153
179
1
8
Interval 2 From Day
P19.9
521
3123
1
161
1
154
179
1
9
Interval 2 To Day
P19.10
522
3124
1
161
1
155
179
1
10
Interval 2 Channel
P19.11
499
NA
NA
161
1
156
179
1
11
Interval 3 On Time
P19.12
501
NA
NA
161
1
157
179
1
12
Interval 3 Off Time
P19.13
523
3122
2
161
1
158
179
1
13
Interval 3 From Day
P19.14
524
3123
2
161
1
159
179
1
14
Interval 3 To Day
P19.15
525
3124
2
161
1
160
179
1
15
Interval 3 Channel
P19.16
503
NA
NA
161
1
161
179
1
16
Interval 4 On Time
P19.17
505
NA
NA
161
1
162
179
1
17
Interval 4 Off Time
P19.18
526
3122
3
161
1
163
179
1
18
Interval 4 From Day
P19.19
527
3123
3
161
1
164
179
1
19
Interval 4 To Day
P19.20
528
3124
3
161
1
165
179
1
20
Interval 4 Channel
Table 188. Parameter ID list, continued