34
GREEN MOTION DC 44/66 EV CHARGER INSTALLATION MANUAL
MN192006EN March 2023 www.eaton.com
00 Title
Figure 23. Location of the three cam locks at the right side of the unit
Step 2.
The front door can be opened sideway.
8.2 How to put the unit as out of order
The Green Motion DC 44/66 EV charger can be set as out of order by following the steps below:
1. On-site method: Press the emergency stop button.
2. Remote method: Access the Eaton Charging network manager and set the unit as out of order.
8.3 Replace the SIM card
To replace the SIM card, proceed as follows:
Step 1.
Remove the existing SIM card from the card slot. See Chapter 7.2.2.
Step 2.
Insert the new SIM card into the card slot. See Chapter 7.2.2.
8.4 Cleaning or replacing filters
Please make sure that the fans are turned off and that the EV charger is not in use during the maintenance
operation. Moving fans can be dangerous and cause finger injuries.
Before starting connection operations, make sure that the external AC-line main switch is disconnected, and
circuit breakers are open.
Check the filters on a yearly basis to ensure they are not obstructed and they work properly. In case of
obstruction, filters need to be replaced as soon as possible. In case of obstruction, Eaton recommends not
to use the unit and to wait for the replacement of the filters.
Before starting the operation, please contact your Eaton service representative for the new filter reference.