Title
Figure 13. Location of the openings for the AC GRID and communication cables
6.3 Electrical connection and terminals
Follow the next steps to connect the EV charger to the power supply:
Step 1.
Open the front door of the EV charger. Please refer to Chapter 8.1 of this manual on how to open the Green
Motion DC 44/66 EV charger housing.
Step 2.
Insert the AC GRID cables into the unit (see Figure 13). The openings for the AC GRID cables and the
communication cable are located on the bottom-left side of the EV charger.
Before starting the connection operations, ensure that the external AC-line main switch is disconnected, and
circuit breakers are open.
The Green Motion DC 44/66 EV charger must not be used in an IT electrical distribution system.
Tag
Description
1
Hole for the AC GRID cables, internal view bottom-left
2
Hole for the Ethernet cable
1
2