![Eaton Green Motion DC 44/66 Installation Manual Download Page 24](http://html1.mh-extra.com/html/eaton/green-motion-dc-44-66/green-motion-dc-44-66_installation-manual_3692091024.webp)
20
GREEN MOTION DC 44/66 EV CHARGER INSTALLATION MANUAL
MN192006EN March 2023 www.eaton.com
00 Title
Eaton recommends the use of the equipment in Table 7 as protective devices.
Table 7. Eaton recommendations for protective devices for Green Motion DC 44/66 EV charger
A d detailed connection diagram of the Green Motion DC 22 EV charger in Figure 20 shows the main components,
including the input switch, EMI filter, surge protection, power module, and the charging outputs. the power modules
and the charging outputs. The third 22 kV power module (PM) is represented by a dashedYeYeah line, which means that
it is only available in the Green Motion DC 66 EV charger version.
Figure 12. Detailed connection diagram of the EV charger
Tag
Description
1
EMI filter
2
Auxiliary control
3
AC-DC power modules
4
Input, 3 x 400 V
AC
5
Output, CHAdeMO
Output, CCS
CHAdeMO/CCS control interface
Green Motion DC 44
Green Motion DC 66
Type of protective device
80 A breaker for 3-phase 64 A
charging current
125 A breaker for 3-phase 96 A
charging current
Eaton product recommendation
AZ-3N-C80
AZ-3N-C125
Article number
211803
211813
SQ1
L1 L2 L3 N
SPD
F1
L2 N
PE
A1
A2 Riso
PE
PE
L1 L2 L3 N
PM1
22 kW
N
L3
L2
L1
PM3
22 kW
PM1
22 kW
MCB1
MCB2
MCB3
CHAdeMO
CSS2
CHAdeMO/
CSS2 CTRL
PE
N
L3
L2
L1
N
L3
L2
L1
1
2
3
5
4
6
6
7
7