ET5050 Crimp machine operator´s manual E-EQCR-TT003-E2 May 2019
Adapter dies (ET5040C-0001) and 32
mm dies (ET5040C-M320S) must be
installed for calibration procedure as
directed. (See figure 61). Follow safe
tooling installation instructions.
Press the motor on button to activate
the hydraulic motor and then crimp
onto the small end of the mandrel
until the green light no longer is
illuminated. Retract the crimp head
and remove the mandrel.
Install small end of mandrel
as directed. (See figure 62)
(ET5040C-0019 tool)
Figure 61
Figure 63
Figure 62
Motor On
Advance
KEEP HANDS CLEAR.
!
Rotate the calibration tool and insert
the large end of the mandrel into the
crimp head and advance the crimp
tooling by depressing the advance
button until the green light no longer
is illuminated. (See figure 64).
When fully advanced, the advance
button illumination will turn off
indicating head is fully advanced.
The display screen will change
showing calibration complete. (See
figure 65) Fully retract head and
remove calibration tool and press
the enter button.
Figure 64
Figure 65
Retract
Advance
!
Settings
Setting #8 - calibration procedure