DOCUMENT 1218
REV. B
Instruction Manual
AGS-LED
312 LED Series
300mm and 400mm
96
Power Cord Base Plate
For external power cord option; external power cord is used, the power cord base plate will be
needed to install the power cord and frangible power coupling.
Grounding Wire
12 AWG green yellow grounding extension wire is supplied with the sign to extend sign
grounding wire to adjacent grounding rod. This wire may be replaced with a grounding wire of a
different color, as long as the new wire is at least 12 AWG, or equivalent, minimum.
Cable Ties
If the optional external power cable is used, we recommend using UV Resistant cable tie, to
resist degradation over time. The cable ties should be used to tie the external power cord to the
closest sign leg.
*Note: For signs with the stainless steel safety tether option,
do not
use cable ties on the
tether.
Heat Shrink Kit
Heat Shrink Kits are recommended for retention of series circuit primary field connections. See
the Crouse-Hinds Sales Catalog for our “HSK” Heat Shrink Kit.
Conduit Elbow
A 50mm [2 inch] conduit elbow is recommended to be installed between the Isolation
Transformer Housing and the power leg. This will prevent the housing from being installed
directly under the sign, allowing ease of maintenance of the isolation transformer.