DOCUMENT 1218
REV. B
Instruction Manual
AGS-LED
312 LED Series
300mm and 400mm
80
Figure 53. TP312 1 MOD LED Wiring Diagram
300mm
400mm
Single Faced
Double Faced
Single Faced
Double Faced
Jumper Setting
Typical VA (6.6A)
15.9
17.4
19.9
22.2
Isolation Transformer (5.5A)*
25W
25W
25W
30/45W
Isolation Transformer (3 STEP)*
25W
25W
30/45W
30/45W
Isolation Transformer (5 STEP)*
30/45W
30/45W
65W
65W
Table 10. TP312 1 MOD Jumper Settings and Apparent Power
* Isolation transformer for number of steps on a CCR. 5.5A is a dedicated Sign circuit.
Power Supply
61171-2
J200 (P1)
J200 (P2)
+
EATON
-